{"title":"VOLTAMMETRIC DETERMINATION OF ESTRADIOL IN MILK AND PHARMACEUTICALS BASED ON FUMED-SILICA MODIFIED CARBON PASTE ELECTRODE","authors":"A. Özcan, Duygu Topçuoğulları, A. Özcan","doi":"10.18038/AUBTDA.430622","DOIUrl":null,"url":null,"abstract":"In this study, modification of carbon paste electrode (CPE) with a nano-structured substance, fumed silica (FS), was investigated to develop a voltammetric method for the determination of an endocrine disrupting chemical, estradiol (EST). FS prominently increased the voltammetric response of CPE towards EST. The parameters that affect the volmametric performance of modified CPE were examined to find the optimal conditions. Modified electrode showed a linear response towards EST between the concentration values of 0.1 mM and 15.0 mM EST. Limit of detection value for the method developed was calculated as 0.023 mM. Production reproducibility of the modified electrode was obtained as 3.6 %. The voltammetric behavior of EST was also examined in the presence of different possible substances to evaluate their interference effects. The modified electrode successfully discriminated the oxidation potential of EST in the presence of different substances. The determination of EST was tested in milk and pharmaceutical samples to evaluate the analytical performance of the method. The recovery analysis of EST in milk samples showed that the modified electrode can be used safely in these samples. The modified electrode also achieved the determination of EST in pharmaceutical samples.","PeriodicalId":7757,"journal":{"name":"Anadolu University Journal of Science and Technology-A Applied Sciences and Engineering","volume":"63 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2018-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anadolu University Journal of Science and Technology-A Applied Sciences and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18038/AUBTDA.430622","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
In this study, modification of carbon paste electrode (CPE) with a nano-structured substance, fumed silica (FS), was investigated to develop a voltammetric method for the determination of an endocrine disrupting chemical, estradiol (EST). FS prominently increased the voltammetric response of CPE towards EST. The parameters that affect the volmametric performance of modified CPE were examined to find the optimal conditions. Modified electrode showed a linear response towards EST between the concentration values of 0.1 mM and 15.0 mM EST. Limit of detection value for the method developed was calculated as 0.023 mM. Production reproducibility of the modified electrode was obtained as 3.6 %. The voltammetric behavior of EST was also examined in the presence of different possible substances to evaluate their interference effects. The modified electrode successfully discriminated the oxidation potential of EST in the presence of different substances. The determination of EST was tested in milk and pharmaceutical samples to evaluate the analytical performance of the method. The recovery analysis of EST in milk samples showed that the modified electrode can be used safely in these samples. The modified electrode also achieved the determination of EST in pharmaceutical samples.
在这项研究中,研究了纳米结构物质气相二氧化硅(FS)修饰碳糊电极(CPE),以建立一种测定内分泌干扰化学物质雌二醇(EST)的伏安法。FS显著提高了CPE对EST的伏安响应,考察了影响改性CPE伏安性能的参数,找出了最佳条件。在0.1 mM ~ 15.0 mM EST浓度范围内,修饰电极对EST呈线性响应,所建立方法的检出限为0.023 mM,生产重现性为3.6%。在不同可能的物质存在下,测试了EST的伏安行为,以评估它们的干扰效应。该修饰电极成功地区分了EST在不同物质存在下的氧化电位。在牛奶和药品样品中进行了EST的测定,以评价该方法的分析性能。对牛奶样品中EST的回收率分析表明,该修饰电极可安全用于牛奶样品中。该修饰电极也实现了药物样品中EST的测定。