D. Ilić, M. Žarković, M. Milić, Đorđe E Jovanović, Radmila Partonjić, Nikola Stanojević
{"title":"Fuzzy logic expert system for assessing the condition of the HV motor stator insulation system","authors":"D. Ilić, M. Žarković, M. Milić, Đorđe E Jovanović, Radmila Partonjić, Nikola Stanojević","doi":"10.5937/zeint31-34709","DOIUrl":null,"url":null,"abstract":"During operation, the electrical insulation system (EIS) of high-voltage motors is exposed to various factors that can accelerate its aging. Timely knowledge of the actual state of the EIS is of great help in allocating funds for service activities. The condition of the EIS of the HV motor can be assessed to some extent by performing available electrical tests. A major shortcoming is the lack of accuracy and the lack of well-defined criteria in the current standards. In that way, a potential error can bias the evaluation of recorded results. The paper proposes the use of a fuzzy logic expert system for assessing the condition of EIS stators of HV motors based on the results of electrical measurements. Also, the proposed fuzzy approach is fully discussed. The created expert system fully relies on the criteria defined in the IS32-Internal Standard of PE EPS.","PeriodicalId":31629,"journal":{"name":"Zbornik Radova Elektrotehnicki Institut Nikola Tesla","volume":"20 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zbornik Radova Elektrotehnicki Institut Nikola Tesla","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5937/zeint31-34709","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
During operation, the electrical insulation system (EIS) of high-voltage motors is exposed to various factors that can accelerate its aging. Timely knowledge of the actual state of the EIS is of great help in allocating funds for service activities. The condition of the EIS of the HV motor can be assessed to some extent by performing available electrical tests. A major shortcoming is the lack of accuracy and the lack of well-defined criteria in the current standards. In that way, a potential error can bias the evaluation of recorded results. The paper proposes the use of a fuzzy logic expert system for assessing the condition of EIS stators of HV motors based on the results of electrical measurements. Also, the proposed fuzzy approach is fully discussed. The created expert system fully relies on the criteria defined in the IS32-Internal Standard of PE EPS.
高压电机电气绝缘系统在运行过程中受到各种因素的影响,加速其老化。及时了解环境影响报告书的实际情况,对为服务活动分配资金有很大帮助。通过进行现有的电气试验,可以在一定程度上评估高压电机的EIS状况。现行标准的一个主要缺点是缺乏准确性和缺乏明确定义的标准。这样,一个潜在的错误可能会使记录结果的评估产生偏差。本文提出了一种基于电气测量结果的模糊逻辑专家系统来评估高压电机EIS定子的状态。并对所提出的模糊方法进行了充分的讨论。所创建的专家系统完全依赖于is32 - PE EPS内部标准中定义的标准。