{"title":"Fully automatic estimation of global left ventricular systolic function using deep learning in transoesophageal echocardiography.","authors":"Erik Andreas Rye Berg, Anders Austlid Taskén, Trym Nordal, Bjørnar Grenne, Torvald Espeland, Idar Kirkeby-Garstad, Håvard Dalen, Espen Holte, Stian Stølen, Svend Aakhus, Gabriel Kiss","doi":"10.1093/ehjimp/qyad007","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>To improve monitoring of cardiac function during major surgery and intensive care, we have developed a method for fully automatic estimation of mitral annular plane systolic excursion (auto-MAPSE) using deep learning in transoesophageal echocardiography (TOE). The aim of this study was a clinical validation of auto-MAPSE in patients with heart disease.</p><p><strong>Methods and results: </strong>TOE recordings were collected from 185 consecutive patients without selection on image quality. Deep-learning-based auto-MAPSE was trained and optimized from 105 patient recordings. We assessed auto-MAPSE feasibility, and agreement and inter-rater reliability with manual reference in 80 patients with and without electrocardiogram (ECG) tracings. Mean processing time for auto-MAPSE was 0.3 s per cardiac cycle/view. Overall feasibility was >90% for manual MAPSE and ECG-enabled auto-MAPSE and 82% for ECG-disabled auto-MAPSE. Feasibility in at least two walls was ≥95% for all methods. Compared with manual reference, bias [95% limits of agreement (LoA)] was -0.5 [-4.0, 3.1] mm for ECG-enabled auto-MAPSE and -0.2 [-4.2, 3.6] mm for ECG-disabled auto-MAPSE. Intra-class correlation coefficient (ICC) for consistency was 0.90 and 0.88, respectively. Manual inter-observer bias [95% LoA] was -0.9 [-4.7, 3.0] mm, and ICC was 0.86.</p><p><strong>Conclusion: </strong>Auto-MAPSE was fast and highly feasible. Inter-rater reliability between auto-MAPSE and manual reference was good. Agreement between auto-MAPSE and manual reference did not differ from manual inter-observer agreement. As the principal advantages of deep-learning-based assessment are speed and reproducibility, auto-MAPSE has the potential to improve real-time monitoring of left ventricular function. This should be investigated in relevant clinical settings.</p>","PeriodicalId":94317,"journal":{"name":"European heart journal. Imaging methods and practice","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11195714/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European heart journal. Imaging methods and practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/ehjimp/qyad007","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/5/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Aims: To improve monitoring of cardiac function during major surgery and intensive care, we have developed a method for fully automatic estimation of mitral annular plane systolic excursion (auto-MAPSE) using deep learning in transoesophageal echocardiography (TOE). The aim of this study was a clinical validation of auto-MAPSE in patients with heart disease.
Methods and results: TOE recordings were collected from 185 consecutive patients without selection on image quality. Deep-learning-based auto-MAPSE was trained and optimized from 105 patient recordings. We assessed auto-MAPSE feasibility, and agreement and inter-rater reliability with manual reference in 80 patients with and without electrocardiogram (ECG) tracings. Mean processing time for auto-MAPSE was 0.3 s per cardiac cycle/view. Overall feasibility was >90% for manual MAPSE and ECG-enabled auto-MAPSE and 82% for ECG-disabled auto-MAPSE. Feasibility in at least two walls was ≥95% for all methods. Compared with manual reference, bias [95% limits of agreement (LoA)] was -0.5 [-4.0, 3.1] mm for ECG-enabled auto-MAPSE and -0.2 [-4.2, 3.6] mm for ECG-disabled auto-MAPSE. Intra-class correlation coefficient (ICC) for consistency was 0.90 and 0.88, respectively. Manual inter-observer bias [95% LoA] was -0.9 [-4.7, 3.0] mm, and ICC was 0.86.
Conclusion: Auto-MAPSE was fast and highly feasible. Inter-rater reliability between auto-MAPSE and manual reference was good. Agreement between auto-MAPSE and manual reference did not differ from manual inter-observer agreement. As the principal advantages of deep-learning-based assessment are speed and reproducibility, auto-MAPSE has the potential to improve real-time monitoring of left ventricular function. This should be investigated in relevant clinical settings.