Iodine quantification in dual-energy mammography: linearity, bias and variability

G. Pacheco-Guevara, J. Castillo-Lopez, Y. Villaseñor-Navarro, M. Brandan
{"title":"Iodine quantification in dual-energy mammography: linearity, bias and variability","authors":"G. Pacheco-Guevara, J. Castillo-Lopez, Y. Villaseñor-Navarro, M. Brandan","doi":"10.1117/12.2625782","DOIUrl":null,"url":null,"abstract":"Contrast-enhanced digital mammography (CEDM) is used to detect iodine uptake in breast lesions. Iodine concentrations inside or around breast lesions could be used as a biomarker, provided a properly characterized quantification method is implemented. In this work, we have evaluated a method to quantify iodine concentrations in CEDM in terms of its intrinsic linearity, bias and variability. This evaluation was performed in a virtual clinical trial (VCT) environment, simulating anthropomorphic breast phantoms containing solid and liquid lesions with different iodine concentrations. Our results showed that anatomical variables such as breast size and lesion size and composition have a considerable effect on the iodine quantification. The method was linear in the clinical iodine concentration range, and showed an approximately constant 1 mg/cm2 bias in the 0 – 2 mg/cm2 range for both solid and liquid lesions. Corrections were proposed that reduced the variability due to breast size, lesion size, and composition.","PeriodicalId":92005,"journal":{"name":"Breast imaging : 11th International Workshop, IWDM 2012, Philadelphia, PA, USA, July 8-11, 2012 : proceedings. International Workshop on Breast Imaging (11th : 2012 : Philadelphia, Pa.)","volume":"7 1","pages":"1228609 - 1228609-8"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Breast imaging : 11th International Workshop, IWDM 2012, Philadelphia, PA, USA, July 8-11, 2012 : proceedings. International Workshop on Breast Imaging (11th : 2012 : Philadelphia, Pa.)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2625782","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Contrast-enhanced digital mammography (CEDM) is used to detect iodine uptake in breast lesions. Iodine concentrations inside or around breast lesions could be used as a biomarker, provided a properly characterized quantification method is implemented. In this work, we have evaluated a method to quantify iodine concentrations in CEDM in terms of its intrinsic linearity, bias and variability. This evaluation was performed in a virtual clinical trial (VCT) environment, simulating anthropomorphic breast phantoms containing solid and liquid lesions with different iodine concentrations. Our results showed that anatomical variables such as breast size and lesion size and composition have a considerable effect on the iodine quantification. The method was linear in the clinical iodine concentration range, and showed an approximately constant 1 mg/cm2 bias in the 0 – 2 mg/cm2 range for both solid and liquid lesions. Corrections were proposed that reduced the variability due to breast size, lesion size, and composition.
双能乳房x光检查中的碘定量:线性、偏倚和可变性
对比增强数字乳房x线摄影(CEDM)用于检测乳腺病变中的碘摄取。乳腺病变内部或周围的碘浓度可作为一种生物标志物,前提是实施一种适当的表征定量方法。在这项工作中,我们评估了一种定量碘浓度的方法,根据其固有的线性,偏差和可变性。该评估是在虚拟临床试验(VCT)环境中进行的,模拟含有不同碘浓度的固体和液体病变的拟人化乳房幻象。我们的结果表明,解剖变量,如乳房大小和病变的大小和组成有相当大的影响碘定量。该方法在临床碘浓度范围内呈线性,并且在0 - 2 mg/cm2范围内显示出近似恒定的1 mg/cm2偏置。修正建议减少由于乳房大小,病变大小和组成的可变性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信