G. Pacheco-Guevara, J. Castillo-Lopez, Y. Villaseñor-Navarro, M. Brandan
{"title":"Iodine quantification in dual-energy mammography: linearity, bias and variability","authors":"G. Pacheco-Guevara, J. Castillo-Lopez, Y. Villaseñor-Navarro, M. Brandan","doi":"10.1117/12.2625782","DOIUrl":null,"url":null,"abstract":"Contrast-enhanced digital mammography (CEDM) is used to detect iodine uptake in breast lesions. Iodine concentrations inside or around breast lesions could be used as a biomarker, provided a properly characterized quantification method is implemented. In this work, we have evaluated a method to quantify iodine concentrations in CEDM in terms of its intrinsic linearity, bias and variability. This evaluation was performed in a virtual clinical trial (VCT) environment, simulating anthropomorphic breast phantoms containing solid and liquid lesions with different iodine concentrations. Our results showed that anatomical variables such as breast size and lesion size and composition have a considerable effect on the iodine quantification. The method was linear in the clinical iodine concentration range, and showed an approximately constant 1 mg/cm2 bias in the 0 – 2 mg/cm2 range for both solid and liquid lesions. Corrections were proposed that reduced the variability due to breast size, lesion size, and composition.","PeriodicalId":92005,"journal":{"name":"Breast imaging : 11th International Workshop, IWDM 2012, Philadelphia, PA, USA, July 8-11, 2012 : proceedings. International Workshop on Breast Imaging (11th : 2012 : Philadelphia, Pa.)","volume":"7 1","pages":"1228609 - 1228609-8"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Breast imaging : 11th International Workshop, IWDM 2012, Philadelphia, PA, USA, July 8-11, 2012 : proceedings. International Workshop on Breast Imaging (11th : 2012 : Philadelphia, Pa.)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2625782","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Contrast-enhanced digital mammography (CEDM) is used to detect iodine uptake in breast lesions. Iodine concentrations inside or around breast lesions could be used as a biomarker, provided a properly characterized quantification method is implemented. In this work, we have evaluated a method to quantify iodine concentrations in CEDM in terms of its intrinsic linearity, bias and variability. This evaluation was performed in a virtual clinical trial (VCT) environment, simulating anthropomorphic breast phantoms containing solid and liquid lesions with different iodine concentrations. Our results showed that anatomical variables such as breast size and lesion size and composition have a considerable effect on the iodine quantification. The method was linear in the clinical iodine concentration range, and showed an approximately constant 1 mg/cm2 bias in the 0 – 2 mg/cm2 range for both solid and liquid lesions. Corrections were proposed that reduced the variability due to breast size, lesion size, and composition.