Enhancing tunability of liquid storage tanks to function as deep tuned liquid dampers by use of a submerged stretched membrane

Tanmoy Konar, Anupama Das, A. Ghosh
{"title":"Enhancing tunability of liquid storage tanks to function as deep tuned liquid dampers by use of a submerged stretched membrane","authors":"Tanmoy Konar, Anupama Das, A. Ghosh","doi":"10.1002/stc.3109","DOIUrl":null,"url":null,"abstract":"This is a study on a deep, liquid‐containing tank, such as an overhead water tank on a building, with a vertically submerged stretched membrane (SSM). Here, instead of the sloshing mode, which can become detuned and also affords a low damper mass ratio, the impulsive liquid–membrane interacting system is designed to serve as a dynamic vibration absorber. The requirement of tuning the frequency of the impulsive liquid–membrane interacting system to the structural frequency can be achieved without any imposition on the tank dimensions, which are generally fixed from the tank's functional requirements. The system frequency would remain unchanged so long the membrane would remain submerged below a minimum liquid depth, thereby allowing fluctuation of liquid level within a prescribed range of the tank depth. The formulation for obtaining the frequency of the impulsive liquid–membrane interacting system is derived, using the sub‐domain partition approach. It is seen that through suitable adjustment of the design parameters of the membrane, the proposed tank damper can be tuned to both short‐period and to long‐period structures. Further, the impulsive liquid mass, which otherwise has no role to play in the damping mechanism of a tuned liquid damper (TLD), is here utilized to absorb and dissipate the vibrational energy. Through a time‐domain study considering recorded seismic accelerograms, the significant control effectiveness of the proposed damper system is illustrated. Further, the results obtained from the equivalent mechanical model of the structure–damper system are compared with those from a finite element analysis of the fluid–structure system in the ANSYS Workbench environment.","PeriodicalId":22049,"journal":{"name":"Structural Control and Health Monitoring","volume":"10 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Structural Control and Health Monitoring","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/stc.3109","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

This is a study on a deep, liquid‐containing tank, such as an overhead water tank on a building, with a vertically submerged stretched membrane (SSM). Here, instead of the sloshing mode, which can become detuned and also affords a low damper mass ratio, the impulsive liquid–membrane interacting system is designed to serve as a dynamic vibration absorber. The requirement of tuning the frequency of the impulsive liquid–membrane interacting system to the structural frequency can be achieved without any imposition on the tank dimensions, which are generally fixed from the tank's functional requirements. The system frequency would remain unchanged so long the membrane would remain submerged below a minimum liquid depth, thereby allowing fluctuation of liquid level within a prescribed range of the tank depth. The formulation for obtaining the frequency of the impulsive liquid–membrane interacting system is derived, using the sub‐domain partition approach. It is seen that through suitable adjustment of the design parameters of the membrane, the proposed tank damper can be tuned to both short‐period and to long‐period structures. Further, the impulsive liquid mass, which otherwise has no role to play in the damping mechanism of a tuned liquid damper (TLD), is here utilized to absorb and dissipate the vibrational energy. Through a time‐domain study considering recorded seismic accelerograms, the significant control effectiveness of the proposed damper system is illustrated. Further, the results obtained from the equivalent mechanical model of the structure–damper system are compared with those from a finite element analysis of the fluid–structure system in the ANSYS Workbench environment.
利用浸没拉伸膜增强储液罐作为深度调谐液体阻尼器的可调性
这是一项关于深层含液水箱的研究,例如建筑物上的高架水箱,具有垂直淹没拉伸膜(SSM)。在这里,代替晃动模式,使其失谐,也提供了一个低阻尼器质量比,设计脉冲液膜相互作用系统作为一个动态减振器。将脉冲液膜相互作用系统的频率调整到结构频率的要求可以在不影响罐尺寸的情况下实现,罐的尺寸通常是根据罐的功能要求固定的。系统频率将保持不变,只要膜保持在最低液体深度以下,从而允许在规定的水箱深度范围内的液位波动。利用子域划分法推导了脉冲液膜相互作用系统频率的计算公式。可以看出,通过适当调整膜的设计参数,所提出的储罐阻尼器既可以调整到短周期结构,也可以调整到长周期结构。此外,在调谐液体阻尼器(TLD)的阻尼机制中没有作用的脉冲液体质量在这里被用来吸收和消散振动能量。通过考虑地震加速度记录的时域研究,说明了所提出的阻尼系统的显著控制效果。在ANSYS Workbench环境下,将结构-阻尼器系统等效力学模型与流固耦合系统有限元分析结果进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信