Z. Yang, F. Zhang, Dingbin Shen, Ming Wang, Dan Zhou, Wei Tong
{"title":"Design of High Reliability Control Strategy for Automatic Fire Protection System of Offshore Booster Station","authors":"Z. Yang, F. Zhang, Dingbin Shen, Ming Wang, Dan Zhou, Wei Tong","doi":"10.1109/ICMCCE51767.2020.00157","DOIUrl":null,"url":null,"abstract":"The fire safety of offshore booster station has an extremely important impact on the reliable operation of the whole offshore wind farm. The article establishes the corresponding fire protection scheme around the offshore wind turbine group, offshore booster station and the on-land central control center of the offshore wind farm. Among them, each offshore wind turbine, offshore booster station and onshore centralized control center are equipped with independent fire alarm systems. The inspiratory smoke detector and point type composite smoke and temperature detector are mainly used to confirm the secondary alarm. At the same time, the fire extinguishing systems of offshore wind turbines, offshore booster stations and on-land control centers are: high-pressure CO2 fire extinguishing system, fine water mist fire extinguishing system and water spray fire extinguishing system. Finally, combined with an engineering case, the fire protection scheme of an offshore wind farm is designed.","PeriodicalId":6712,"journal":{"name":"2020 5th International Conference on Mechanical, Control and Computer Engineering (ICMCCE)","volume":"18 1","pages":"712-716"},"PeriodicalIF":0.0000,"publicationDate":"2020-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 5th International Conference on Mechanical, Control and Computer Engineering (ICMCCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICMCCE51767.2020.00157","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
The fire safety of offshore booster station has an extremely important impact on the reliable operation of the whole offshore wind farm. The article establishes the corresponding fire protection scheme around the offshore wind turbine group, offshore booster station and the on-land central control center of the offshore wind farm. Among them, each offshore wind turbine, offshore booster station and onshore centralized control center are equipped with independent fire alarm systems. The inspiratory smoke detector and point type composite smoke and temperature detector are mainly used to confirm the secondary alarm. At the same time, the fire extinguishing systems of offshore wind turbines, offshore booster stations and on-land control centers are: high-pressure CO2 fire extinguishing system, fine water mist fire extinguishing system and water spray fire extinguishing system. Finally, combined with an engineering case, the fire protection scheme of an offshore wind farm is designed.