Reflux after intravitreal injection: an anterior segment optical coherence tomography study

Ismail Ersan, Aydın Yildiz
{"title":"Reflux after intravitreal injection: an anterior segment optical coherence tomography study","authors":"Ismail Ersan, Aydın Yildiz","doi":"10.15406/AOVS.2020.10.00376","DOIUrl":null,"url":null,"abstract":"Purpose: To investigate the intraocular pressure and conjunctival thickness changes following the intravitreal injection Methods: Sixty eyes of 60 patients having intravitreal injection for age-related macular degeneration, macular edema associated with diabetes, central retinal vein occlusion, and branch retinal vein occlusion were enrolled. Intraocular pressure (IOP) was measured by Tonopen-Avia (Reichert Inc., NY, USA) in sitting position and five superior-temporal conjunctival images were obtained using the Anterior Segment 5 Line Raster scanning protocol of Cirrus HD-OCT 4000 (Carl Zeiss Meditec, Dublin, CA, USA) just before the intravitreal injection. 0.05 ml bevacizumab with 27-gauge needle, 0.05 ml ranibizumab with 30-gauge needle, or dexamethasone implant with 23-gauge needle was injected into the vitreous cavity. The second IOP measurements and OCT measurements were taken within 5 mins of injection. Results: The ranibizumab group included 25 subjects, the bevacizumab group included 23 subjects, and the dexamethasone group included 12 subjects. IOP increases following intravitreal injection were significantly higher in ranibizumab and bevacizumab groups compared with Dexamethasone implant group (p<0.001 and p=0.007, respectively). Although, the increase of conjunctival thickness following the intravitreal injection was highest in Dexamethasone implant group, the differences between the groups did not reach statistically significance (p=0.153). Conclusion: A higher IOP elevation is observed if a small-gauge needle is used for intravitreal injection. The conjunctival thickness changes following the intravitreal injection did not differ between the groups","PeriodicalId":90420,"journal":{"name":"Advances in ophthalmology & visual system","volume":"30 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-02-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in ophthalmology & visual system","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15406/AOVS.2020.10.00376","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To investigate the intraocular pressure and conjunctival thickness changes following the intravitreal injection Methods: Sixty eyes of 60 patients having intravitreal injection for age-related macular degeneration, macular edema associated with diabetes, central retinal vein occlusion, and branch retinal vein occlusion were enrolled. Intraocular pressure (IOP) was measured by Tonopen-Avia (Reichert Inc., NY, USA) in sitting position and five superior-temporal conjunctival images were obtained using the Anterior Segment 5 Line Raster scanning protocol of Cirrus HD-OCT 4000 (Carl Zeiss Meditec, Dublin, CA, USA) just before the intravitreal injection. 0.05 ml bevacizumab with 27-gauge needle, 0.05 ml ranibizumab with 30-gauge needle, or dexamethasone implant with 23-gauge needle was injected into the vitreous cavity. The second IOP measurements and OCT measurements were taken within 5 mins of injection. Results: The ranibizumab group included 25 subjects, the bevacizumab group included 23 subjects, and the dexamethasone group included 12 subjects. IOP increases following intravitreal injection were significantly higher in ranibizumab and bevacizumab groups compared with Dexamethasone implant group (p<0.001 and p=0.007, respectively). Although, the increase of conjunctival thickness following the intravitreal injection was highest in Dexamethasone implant group, the differences between the groups did not reach statistically significance (p=0.153). Conclusion: A higher IOP elevation is observed if a small-gauge needle is used for intravitreal injection. The conjunctival thickness changes following the intravitreal injection did not differ between the groups
玻璃体内注射后反流:前段光学相干断层扫描研究
目的:观察玻璃体注射后眼压和结膜厚度的变化。方法:选择老年性黄斑变性、糖尿病性黄斑水肿、视网膜中央静脉阻塞、视网膜分支静脉阻塞患者60例,60眼玻璃体注射。坐位眼内压(IOP)由tonopenavia (Reichert Inc., NY, USA)测量,玻璃体注射前使用Cirrus HD-OCT 4000 (Carl Zeiss Meditec, Dublin, CA, USA)的前段5线光栅扫描协议获得5张颞上结膜图像。玻璃体腔内注射贝伐单抗(27号针头)0.05 ml、雷尼单抗(30号针头)0.05 ml或地塞米松植入物(23号针头)。第二次IOP测量和OCT测量在注射后5分钟内进行。结果:雷尼单抗组纳入25例,贝伐单抗组纳入23例,地塞米松组纳入12例。雷尼单抗组和贝伐单抗组玻璃体内注射后IOP升高明显高于地塞米松组(p分别<0.001和p=0.007)。虽然地塞米松种植体组玻璃体内注射后结膜厚度增加最多,但两组间差异无统计学意义(p=0.153)。结论:采用小规针进行玻璃体内注射可提高眼压升高。玻璃体注射后结膜厚度的变化在两组间无差异
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信