Atlas tri-plate standoff insulators' design and test results

J. Elizondo, R. Smelser, P. Aragon, D. Torres, K. Prestwich, K. Nielsen, H. Davis, B. Hinkley
{"title":"Atlas tri-plate standoff insulators' design and test results","authors":"J. Elizondo, R. Smelser, P. Aragon, D. Torres, K. Prestwich, K. Nielsen, H. Davis, B. Hinkley","doi":"10.1109/PPC.1999.823792","DOIUrl":null,"url":null,"abstract":"The Atlas system consists of 96 Marx generators, arranged in a circle. Sets of four generators feed a tri-plate transmission line, and the tri-plate lines in turn feed a central load region. The space between the plates is a nominal 2.00 cm (0.787 inch). This spacing and support of the central plate are provided by a set of insulators referred to as the tri-plate standoff insulators (TSI). The insulators were designed to provide the required mechanical support, ease of replacement or removal for maintenance, and the electric field gradient standoff. Two materials were selected: one was chosen because it has reasonable mechanical properties and a dielectric constant close to that of oil (polypropylene /spl epsiv/=2.3); the other material was selected because of its increased mechanical strength, even though the dielectric constant is higher than that of oil (Nylon MC 901 and 907 /spl epsiv/=3.7). Testing of the insulators was performed in a three-foot diameter tri-plate assembly. The test setup accepts four insulators at a time. The nominal operational voltage for the tri-plates is 240 kV at a t/sub eff/ of 0.87 /spl mu/s. The testing was performed at up to 450 kV with a t/sub eff/ of 2.8 /spl mu/s. The insulators were successfully tested until oil breakdown between the plates was reached, with no insulator flashover.","PeriodicalId":11209,"journal":{"name":"Digest of Technical Papers. 12th IEEE International Pulsed Power Conference. (Cat. No.99CH36358)","volume":"293 1","pages":"1407-1409 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"1999-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digest of Technical Papers. 12th IEEE International Pulsed Power Conference. (Cat. No.99CH36358)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PPC.1999.823792","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The Atlas system consists of 96 Marx generators, arranged in a circle. Sets of four generators feed a tri-plate transmission line, and the tri-plate lines in turn feed a central load region. The space between the plates is a nominal 2.00 cm (0.787 inch). This spacing and support of the central plate are provided by a set of insulators referred to as the tri-plate standoff insulators (TSI). The insulators were designed to provide the required mechanical support, ease of replacement or removal for maintenance, and the electric field gradient standoff. Two materials were selected: one was chosen because it has reasonable mechanical properties and a dielectric constant close to that of oil (polypropylene /spl epsiv/=2.3); the other material was selected because of its increased mechanical strength, even though the dielectric constant is higher than that of oil (Nylon MC 901 and 907 /spl epsiv/=3.7). Testing of the insulators was performed in a three-foot diameter tri-plate assembly. The test setup accepts four insulators at a time. The nominal operational voltage for the tri-plates is 240 kV at a t/sub eff/ of 0.87 /spl mu/s. The testing was performed at up to 450 kV with a t/sub eff/ of 2.8 /spl mu/s. The insulators were successfully tested until oil breakdown between the plates was reached, with no insulator flashover.
阿特拉斯三板绝缘子的设计和试验结果
阿特拉斯系统由96个马克思发电机组成,排列成一个圆圈。四组发电机为三板传输线供电,三板传输线依次为中心负荷区供电。板之间的空间是一个标称2.00厘米(0.787英寸)。这种间距和中央板的支持是由一组称为三板隔离绝缘子(TSI)的绝缘子提供的。绝缘体的设计是为了提供所需的机械支持,易于更换或拆卸以进行维护,以及电场梯度隔离。选择两种材料:选择一种材料是因为它具有合理的力学性能,介电常数接近于油(聚丙烯/spl epsiv/=2.3);选择另一种材料是因为其机械强度增加,即使介电常数高于油(尼龙MC 901和907 /spl epsiv/=3.7)。绝缘子的测试是在一个三英尺直径的三板组件中进行的。测试装置一次接受四个绝缘体。三极板的标称工作电压为240千伏,电压为0.87 /磅/秒。测试在高达450 kV的电压下进行,t/sub / eff/为2.8 /spl mu/s。绝缘子测试成功,直到达到板间的油击穿,没有绝缘子闪络。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信