Hemostatic Shape Memory Polymer Foams With Improved Survival in a Lethal Traumatic Hemorrhage Model

Henry T. Beaman, Ellen Shepherd, J. Satalin, S. Blair, H. Ramcharran, S. Serinelli, L. Gitto, Katheryn Shi Dong, David Fikhman, G. Nieman, S. Schauer, M. B. Monroe
{"title":"Hemostatic Shape Memory Polymer Foams With Improved Survival in a Lethal Traumatic Hemorrhage Model","authors":"Henry T. Beaman, Ellen Shepherd, J. Satalin, S. Blair, H. Ramcharran, S. Serinelli, L. Gitto, Katheryn Shi Dong, David Fikhman, G. Nieman, S. Schauer, M. B. Monroe","doi":"10.2139/ssrn.3864497","DOIUrl":null,"url":null,"abstract":"Although there are many hemostatic agents available for use on the battlefield, uncontrolled hemorrhage is still the primary cause of preventable death. Current hemostatic dressings include QuikClot® Combat Gauze (QCCG) and XStat®, which have inadequate success in reducing mortality. To address this need, a new hemostatic material was developed using shape memory polymer (SMP) foams, which demonstrate biocompatibility, rapid clotting, and shape recovery to fill the wound site. SMP foam hemostatic efficacy was examined in a lethal, noncompressible porcine liver injury model over 6 hours following injury. Wounds were packed with SMP foams, XStat, or QCCG and compared in terms of time to bleeding cessation, total blood loss, and animal survival. The hemostatic material properties and in vitro blood interactions were also characterized. SMP foams decreased blood loss and active bleeding time in comparison with XStat and QCCG. Most importantly, SMP foams increased the 6-hour survival rate by 50% and 37% (vs. XStat and QCCG, respectively) with significant increases in survival times. Based upon in vitro characterizations, this result is attributed to the low stiffness and shape filling capabilities of SMP foams. This study demonstrates that SMP foams have promise for improving upon current clinically available hemostatic dressings and that hemostatic material properties are important to consider in designing devices for noncompressible bleeding control.","PeriodicalId":8928,"journal":{"name":"Biomaterials eJournal","volume":"20 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"30","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomaterials eJournal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2139/ssrn.3864497","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 30

Abstract

Although there are many hemostatic agents available for use on the battlefield, uncontrolled hemorrhage is still the primary cause of preventable death. Current hemostatic dressings include QuikClot® Combat Gauze (QCCG) and XStat®, which have inadequate success in reducing mortality. To address this need, a new hemostatic material was developed using shape memory polymer (SMP) foams, which demonstrate biocompatibility, rapid clotting, and shape recovery to fill the wound site. SMP foam hemostatic efficacy was examined in a lethal, noncompressible porcine liver injury model over 6 hours following injury. Wounds were packed with SMP foams, XStat, or QCCG and compared in terms of time to bleeding cessation, total blood loss, and animal survival. The hemostatic material properties and in vitro blood interactions were also characterized. SMP foams decreased blood loss and active bleeding time in comparison with XStat and QCCG. Most importantly, SMP foams increased the 6-hour survival rate by 50% and 37% (vs. XStat and QCCG, respectively) with significant increases in survival times. Based upon in vitro characterizations, this result is attributed to the low stiffness and shape filling capabilities of SMP foams. This study demonstrates that SMP foams have promise for improving upon current clinically available hemostatic dressings and that hemostatic material properties are important to consider in designing devices for noncompressible bleeding control.
止血形状记忆聚合物泡沫提高致死性创伤出血模型的存活率
虽然有许多止血剂可用于战场,但不受控制的出血仍然是可预防死亡的主要原因。目前的止血敷料包括QuikClot®战斗纱布(QCCG)和XStat®,它们在降低死亡率方面没有足够的成功。为了满足这一需求,一种使用形状记忆聚合物(SMP)泡沫的新型止血材料被开发出来,这种材料具有生物相容性、快速凝血和形状恢复能力,可以填充伤口部位。在致死性、不可压缩性猪肝损伤模型中观察SMP泡沫止血效果。伤口用SMP泡沫、XStat或QCCG填充,并比较止血时间、总失血量和动物存活率。止血材料的性能和体外血液相互作用也进行了表征。与XStat和QCCG相比,SMP泡沫减少了失血量和活动出血时间。最重要的是,SMP泡沫使6小时存活率提高了50%和37%(分别与XStat和QCCG相比),存活时间显著增加。基于体外表征,这一结果归因于SMP泡沫的低刚度和形状填充能力。这项研究表明,SMP泡沫有望改善目前临床可用的止血敷料,并且在设计不可压缩出血控制装置时,止血材料的性能是重要的考虑因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信