Mechanical Behavior of a Woven Graphite/PMR-15 Composite at Room and Elevated Temperatures Determined from the ±45° Tensile and Iosipescu Shear Tests

M. Gentz, D. Armentrout, P. Rupnowski, L. Kumosa, J. Sutter, M. Kumosa
{"title":"Mechanical Behavior of a Woven Graphite/PMR-15 Composite at Room and Elevated Temperatures Determined from the ±45° Tensile and Iosipescu Shear Tests","authors":"M. Gentz, D. Armentrout, P. Rupnowski, L. Kumosa, J. Sutter, M. Kumosa","doi":"10.1520/CTR11001J","DOIUrl":null,"url":null,"abstract":"Failure and stiffness properties of a woven 8 harness satin (8HS) graphite/PMR-15 composite have been investigated at room temperature and at 315°C by performing the ±45° tensile and Iosipescu tests. Acoustic emission has been monitored during testing. The critical loads for the initiation of damage in the composite have been determined. In particular, the specimen width effect has been investigated in the case of the ±45° specimens by testing the specimens with their width ranging from 12.7–50.8 mm. The results from the high temperature tests have been compared with the room temperature data presented in Refs. 1 and 2. Similar to the room temperature ±45° tests, the shear stresses at the onset of intralaminar damage in the specimens and the shear stresses at the maximum loads at 315°C are significantly affected by the specimen width effect. The trends in the damage initiation stresses and the maximum stresses as a function of specimen width at 315°C have been found to be very similar to the room temperature data with the stresses increasing almost linearly with the specimen width. It has also been shown in this project that the shear stresses at the onset of intralaminar damage and at the maximum load at 315°C depend very strongly on the specimen type. The shear stresses determined at the onset of damage and maximum loads from the Iosipescu tests at 315°C are noticeably higher than the stresses from the ±45° tests. The ±45° tensile test significantly underestimates the room and elevated temperature shear strength properties of the 8HS graphite/PMR-15 composite in comparison with the Iosipescu shear test.","PeriodicalId":15514,"journal":{"name":"Journal of Composites Technology & Research","volume":"52 1","pages":"11065"},"PeriodicalIF":0.0000,"publicationDate":"2003-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Composites Technology & Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1520/CTR11001J","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16

Abstract

Failure and stiffness properties of a woven 8 harness satin (8HS) graphite/PMR-15 composite have been investigated at room temperature and at 315°C by performing the ±45° tensile and Iosipescu tests. Acoustic emission has been monitored during testing. The critical loads for the initiation of damage in the composite have been determined. In particular, the specimen width effect has been investigated in the case of the ±45° specimens by testing the specimens with their width ranging from 12.7–50.8 mm. The results from the high temperature tests have been compared with the room temperature data presented in Refs. 1 and 2. Similar to the room temperature ±45° tests, the shear stresses at the onset of intralaminar damage in the specimens and the shear stresses at the maximum loads at 315°C are significantly affected by the specimen width effect. The trends in the damage initiation stresses and the maximum stresses as a function of specimen width at 315°C have been found to be very similar to the room temperature data with the stresses increasing almost linearly with the specimen width. It has also been shown in this project that the shear stresses at the onset of intralaminar damage and at the maximum load at 315°C depend very strongly on the specimen type. The shear stresses determined at the onset of damage and maximum loads from the Iosipescu tests at 315°C are noticeably higher than the stresses from the ±45° tests. The ±45° tensile test significantly underestimates the room and elevated temperature shear strength properties of the 8HS graphite/PMR-15 composite in comparison with the Iosipescu shear test.
编织石墨/PMR-15复合材料在室温和高温下的力学行为,由±45°拉伸和Iosipescu剪切试验确定
通过±45°拉伸和Iosipescu试验,研究了编织8线束缎(8HS)石墨/PMR-15复合材料在室温和315°C下的失效和刚度特性。在测试过程中监测了声发射。确定了复合材料发生损伤的临界载荷。特别是,在±45°试样的情况下,通过测试12.7-50.8 mm的试样宽度,研究了试样宽度效应。高温试验的结果已与参考文献1和2中提供的室温数据进行了比较。与室温±45°试验相似,试件层间损伤开始时的剪应力和315°C时最大载荷下的剪应力受试件宽度效应的显著影响。在315°C时,损伤起始应力和最大应力随试样宽度的变化趋势与室温数据非常相似,应力随试样宽度几乎呈线性增加。该项目还表明,层间损伤开始时的剪切应力和315°C时的最大载荷非常强烈地依赖于试件类型。在315°C的Iosipescu试验中确定的损伤开始时的剪切应力和最大载荷明显高于±45°试验的应力。与Iosipescu剪切试验相比,±45°拉伸试验显著低估了8HS石墨/PMR-15复合材料的室温和高温剪切强度性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信