{"title":"Dose Audits of Patients Undergoing Some Common Radiographic Examinations in Selected Nigerian Hospitals","authors":"L. Bamidele, Osahon. O. David","doi":"10.21608/EJRSA.2019.5325.1053","DOIUrl":null,"url":null,"abstract":"This study aims at determining radiation doses for patients undergoing six (6) common radio graphic examinations in eight X – ray units in the southern part of Nigeria using computational method. Both public and private – owned hospitals were used for the study. Patient data and technical parameters were collected during the examinations. The meanentrance surface air kerma (ESAK) obtained from all the x-rays units considered ranged from 0.35 to 1.96mGy for Chest PA, 1.01 to 17.55mGy for Abdomen PA; 1.08 to 16.14mGy for pelvis AP,1.12 to 10.06mGy for Pelvis LAT, 0.08 to 3.54mGy for Skull AP/PA; 1.07 to 4.61 for Skull LAT, 1.67 to 12.46mGy for Lumber Spine AP, 1.82 to 14.24mGy for Lumber Spine LAT. Local diagnostic reference levels (LDRLs) were established based on the third quartile of ESAKs values. The established LDRLs were compared with previously established DRLs from other countries. The ESAKs values obtained in this study were found to be within the international established DRLs except in few cases.","PeriodicalId":11658,"journal":{"name":"Egyptian Journal of Radiation Sciences and Applications","volume":"43 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Egyptian Journal of Radiation Sciences and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21608/EJRSA.2019.5325.1053","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This study aims at determining radiation doses for patients undergoing six (6) common radio graphic examinations in eight X – ray units in the southern part of Nigeria using computational method. Both public and private – owned hospitals were used for the study. Patient data and technical parameters were collected during the examinations. The meanentrance surface air kerma (ESAK) obtained from all the x-rays units considered ranged from 0.35 to 1.96mGy for Chest PA, 1.01 to 17.55mGy for Abdomen PA; 1.08 to 16.14mGy for pelvis AP,1.12 to 10.06mGy for Pelvis LAT, 0.08 to 3.54mGy for Skull AP/PA; 1.07 to 4.61 for Skull LAT, 1.67 to 12.46mGy for Lumber Spine AP, 1.82 to 14.24mGy for Lumber Spine LAT. Local diagnostic reference levels (LDRLs) were established based on the third quartile of ESAKs values. The established LDRLs were compared with previously established DRLs from other countries. The ESAKs values obtained in this study were found to be within the international established DRLs except in few cases.
在选定的尼日利亚医院进行一些常见放射检查的病人的剂量审计
本研究旨在利用计算方法确定尼日利亚南部8个X射线单位中接受六(6)次普通放射图像检查的患者的辐射剂量。研究对象包括公立医院和私立医院。在检查过程中收集患者资料和技术参数。所有考虑的x射线单元获得的平均入口表面空气kerma (ESAK)在胸部PA为0.35至1.96mGy,腹部PA为1.01至17.55mGy;骨盆AP为1.08 ~ 16.14mGy,骨盆LAT为1.12 ~ 10.06mGy,颅骨AP/PA为0.08 ~ 3.54mGy;颅骨LAT为1.07至4.61毫克,木材脊柱AP为1.67至12.46毫克,木材脊柱LAT为1.82至14.24毫克。根据ESAKs值的第三个四分位数建立局部诊断参考水平(LDRLs)。将已建立的最低限度限制与其他国家以前建立的最低限度限制进行比较。本研究获得的ESAKs值除少数情况外,均在国际确定的drl范围内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信