Insulation monitoring system for XLPE cable containing water sensor and optical fiber

M. Aihara, Y. Ebinuma, M. Minami, M. Murakawa
{"title":"Insulation monitoring system for XLPE cable containing water sensor and optical fiber","authors":"M. Aihara, Y. Ebinuma, M. Minami, M. Murakawa","doi":"10.1109/ICPADM.1991.172179","DOIUrl":null,"url":null,"abstract":"An all-purpose insulation monitoring system for XLPE (cross-linked polyethylene) cables in hot line has been developed. The system measures the dielectric dissipation factor and DC component of charging current, i.e., the two factors which are attracting much attention for evaluation of cable insulation in hot line, and detects water penetration and longitudinal temperature distribution in the cable. Water penetration and longitudinal temperature distribution in the cable are detected by a water-penetration sensor and an optical fiber, respectively, both built into the XLPE cable. The monitoring system has been installed in an actual circuit having a test cable, and a proof test is being conducted on the circuit.<<ETX>>","PeriodicalId":6450,"journal":{"name":"[1991] Proceedings of the 3rd International Conference on Properties and Applications of Dielectric Materials","volume":"45 1","pages":"765-768 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"1991-07-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"[1991] Proceedings of the 3rd International Conference on Properties and Applications of Dielectric Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPADM.1991.172179","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

An all-purpose insulation monitoring system for XLPE (cross-linked polyethylene) cables in hot line has been developed. The system measures the dielectric dissipation factor and DC component of charging current, i.e., the two factors which are attracting much attention for evaluation of cable insulation in hot line, and detects water penetration and longitudinal temperature distribution in the cable. Water penetration and longitudinal temperature distribution in the cable are detected by a water-penetration sensor and an optical fiber, respectively, both built into the XLPE cable. The monitoring system has been installed in an actual circuit having a test cable, and a proof test is being conducted on the circuit.<>
含水传感器和光纤的交联聚乙烯电缆绝缘监测系统
研制了一种通用性强的交联聚乙烯(XLPE)电缆绝缘监测系统。该系统测量了热线电缆绝缘评价中备受关注的两个因素介电损耗系数和充电电流直流分量,并检测了电缆的水侵及纵向温度分布。水侵和电缆的纵向温度分布分别由水侵传感器和光纤检测,两者都内置在XLPE电缆中。监控系统已安装在有测试电缆的实际电路中,并正在对该电路进行验证测试
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信