LIQUID-LIQUID EXTRACTION-SPECTROPHOTOMETRIC DETERMINATION OF MOLYBDENUM USING o-HYDROXYTHIOPHENOLS

A. Zalov, K. Gavazov
{"title":"LIQUID-LIQUID EXTRACTION-SPECTROPHOTOMETRIC DETERMINATION OF MOLYBDENUM USING o-HYDROXYTHIOPHENOLS","authors":"A. Zalov, K. Gavazov","doi":"10.24297/JAC.V10I8.6687","DOIUrl":null,"url":null,"abstract":"27 liquid-liquid extraction-chromogenic systems containing Mo(VI), o-hydroxythiophenol derivative {HTPDs: 2-hydroxy-5-chlorothiophenol (HCTP), 2-hydroxy-5-bromothiophenol (HBTP) or 2-hydroxy-5-iodothiophenol (HITP)} and aromatic amine (AA) were studied. Aniline (An), N-methylaniline (mAn), N,N-dimethylaniline (dAn), o-toluidine (o-Tol), m-toluidine (m-Tol), p-toluidine (p-Tol), 3,4-xylidine (o-Xyl), 2,4-xylidine (m-Xyl), and 2,5-xylidine (p-Xyl) were the examined AAs. Optimization experiments for molybdenum extraction-spectrophotometric determination were performed and the following parameters were found for each of the systems: organic solvent (opt), pH (opt), C HTPD (opt), C AA (opt), shaking time (opt), l (max) and e (max). Under the optimum conditions, the molar ratio of the reacting Mo(V), HTPD and AA was 1:2:2 and the degrees of Mo extraction were R³98.4%. Linear relationships involving the spectral characteristics of the extracted complexes (l max or e max ) and some fundamental properties of the halogen substituent in the HTPD were discussed. The effect of foreign ions was examined and two sensitive, selective and precise procedures for extraction-spectrophotometric determination of molybdenum were proposed. The relative standard deviations for Mo content of (3-5)´10 –4 mass % were 4% (HCTP-An procedure) and 3% (HBTP-An procedure).","PeriodicalId":14904,"journal":{"name":"JOURNAL OF ADVANCES IN CHEMISTRY","volume":"117 1","pages":"3003-3011"},"PeriodicalIF":0.0000,"publicationDate":"2017-04-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JOURNAL OF ADVANCES IN CHEMISTRY","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24297/JAC.V10I8.6687","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

27 liquid-liquid extraction-chromogenic systems containing Mo(VI), o-hydroxythiophenol derivative {HTPDs: 2-hydroxy-5-chlorothiophenol (HCTP), 2-hydroxy-5-bromothiophenol (HBTP) or 2-hydroxy-5-iodothiophenol (HITP)} and aromatic amine (AA) were studied. Aniline (An), N-methylaniline (mAn), N,N-dimethylaniline (dAn), o-toluidine (o-Tol), m-toluidine (m-Tol), p-toluidine (p-Tol), 3,4-xylidine (o-Xyl), 2,4-xylidine (m-Xyl), and 2,5-xylidine (p-Xyl) were the examined AAs. Optimization experiments for molybdenum extraction-spectrophotometric determination were performed and the following parameters were found for each of the systems: organic solvent (opt), pH (opt), C HTPD (opt), C AA (opt), shaking time (opt), l (max) and e (max). Under the optimum conditions, the molar ratio of the reacting Mo(V), HTPD and AA was 1:2:2 and the degrees of Mo extraction were R³98.4%. Linear relationships involving the spectral characteristics of the extracted complexes (l max or e max ) and some fundamental properties of the halogen substituent in the HTPD were discussed. The effect of foreign ions was examined and two sensitive, selective and precise procedures for extraction-spectrophotometric determination of molybdenum were proposed. The relative standard deviations for Mo content of (3-5)´10 –4 mass % were 4% (HCTP-An procedure) and 3% (HBTP-An procedure).
液-液萃取-邻羟基噻吩分光光度法测定钼
研究了含有Mo(VI)、邻羟基噻吩衍生物{htpd: 2-羟基-5-氯噻吩(HCTP)、2-羟基-5-溴噻吩(HBTP)或2-羟基-5-碘噻吩(HITP)}和芳香胺(AA)的27个液-液萃取显色体系。以苯胺(An)、N-甲基苯胺(mAn)、N,N-二甲基苯胺(dAn)、邻甲苯胺(o-Tol)、间甲苯胺(m-Tol)、对甲苯胺(p-Tol)、3,4-二甲苯胺(o-Xyl)、2,4-二甲苯胺(m-Xyl)和2,5-二甲苯胺(p-Xyl)为研究对象。对各体系的有机溶剂(opt)、pH (opt)、C HTPD (opt)、C AA (opt)、振荡时间(opt)、l (max)、e (max)进行了优化实验。在最佳条件下,Mo(V)、HTPD和AA的摩尔比为1:2:2,Mo的提取率为R³98.4%。讨论了萃取物的光谱特征(lmax或emax)与卤代取代基的一些基本性质之间的线性关系。考察了外来离子的影响,提出了两种灵敏、选择性和精确的提取-分光光度法测定钼的方法。(3-5) × 10 -4质量% Mo含量的相对标准偏差分别为4% (htp - a程序)和3% (htp - a程序)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书