Breakage and Elution of CSTD by Oil-based Solvents in Injection Drugs

Kyohei Haruta, Hiroshi Aoi, Kinuko Kimura, Kazuya Okada, C. Mikami, Masaki Murata, Sayo Matsuda, Kana Sado, I. Yoshikawa, Kazuyuki Ikeda
{"title":"Breakage and Elution of CSTD by Oil-based Solvents in Injection Drugs","authors":"Kyohei Haruta, Hiroshi Aoi, Kinuko Kimura, Kazuya Okada, C. Mikami, Masaki Murata, Sayo Matsuda, Kana Sado, I. Yoshikawa, Kazuyuki Ikeda","doi":"10.5649/jjphcs.47.590","DOIUrl":null,"url":null,"abstract":"Busulfex ® is a non-aqueous injection of insoluble Busulfan dissolved in the oil-based solvents Polyethylene Glycol 400 (PEG400) and N,N -Dimethylacetamide (DMA). The use of a closed system transfer device (CSTD) is strongly recom-mended for the preparation of all hazardous drugs, and we use a CSTD for the preparation and administration of anticancer drugs at Nara Medical University Hospital. We experienced a case of frequent blockage of the intravenous route when Busulfex ® was administered. In the present study, when the test solution containing PEG400 and DMA mixed in the same ratio as Busulfex ® was syringe aspirated by CSTD, the CSTD was broken and foreign particles were generated within 3 minutes of aspiration. When DMA was syringe aspirated by CSTD, polycarbonate, the material of CSTD, was eluted, and functional abnormality of CSTD was observed 30 minutes after aspiration. Oil-based solvents are used as additives in many anticancer drugs. The suitability of a CSTD for the preparation of anticancer drugs should be deter-mined by considering not only the hazard classification of the anticancer drug, but also the type and ratio of the additives.","PeriodicalId":14574,"journal":{"name":"Iryo Yakugaku (Japanese Journal of Pharmaceutical Health Care and Sciences)","volume":"51 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iryo Yakugaku (Japanese Journal of Pharmaceutical Health Care and Sciences)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5649/jjphcs.47.590","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Busulfex ® is a non-aqueous injection of insoluble Busulfan dissolved in the oil-based solvents Polyethylene Glycol 400 (PEG400) and N,N -Dimethylacetamide (DMA). The use of a closed system transfer device (CSTD) is strongly recom-mended for the preparation of all hazardous drugs, and we use a CSTD for the preparation and administration of anticancer drugs at Nara Medical University Hospital. We experienced a case of frequent blockage of the intravenous route when Busulfex ® was administered. In the present study, when the test solution containing PEG400 and DMA mixed in the same ratio as Busulfex ® was syringe aspirated by CSTD, the CSTD was broken and foreign particles were generated within 3 minutes of aspiration. When DMA was syringe aspirated by CSTD, polycarbonate, the material of CSTD, was eluted, and functional abnormality of CSTD was observed 30 minutes after aspiration. Oil-based solvents are used as additives in many anticancer drugs. The suitability of a CSTD for the preparation of anticancer drugs should be deter-mined by considering not only the hazard classification of the anticancer drug, but also the type and ratio of the additives.
注射用油基溶剂对CSTD的破坏与洗脱
Busulfex®是一种非水注射剂,不溶性Busulfan溶解在油基溶剂聚乙二醇400 (PEG400)和N,N -二甲基乙酰胺(DMA)中。所有危险药物的制备都强烈推荐使用封闭系统转移装置(CSTD),我们在奈良医科大学医院使用封闭系统转移装置来制备和给药抗癌药物。我们经历了一个病例频繁堵塞静脉途径时,Busulfex®给予。在本研究中,将含有PEG400和DMA与Busulfex®按相同比例混合的测试溶液用CSTD注射器吸入时,CSTD在吸入后3分钟内破裂并产生外来颗粒。用CSTD注射器抽吸DMA时,洗脱CSTD材料聚碳酸酯,抽吸30分钟后观察CSTD功能异常。油基溶剂被用作许多抗癌药物的添加剂。确定CSTD是否适合用于抗癌药物的制备,不仅要考虑抗癌药物的危害分类,还要考虑添加剂的种类和比例。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信