{"title":"Managing to Reproduce Original Carbonate Core Condition: Is Core Initialized Realistically on Three-Dimensional Geometry?","authors":"H. Yonebayashi, Takaaki Uetani, Hiromi Kaido","doi":"10.2118/208860-ms","DOIUrl":null,"url":null,"abstract":"\n In this study, we established initial water saturation (Swi) using three techniques: (1) the dynamic displacement technique, (2) the porous plate technique, and (3) the vacuum saturation technique. A unique heterogeneous carbonate reservoir rock sample (1.5-inch diameter and 3-inches long) was used repeatedly to compare the techniques without an uncertainty of different cores. After establishing Swi by each initialization technique, the cross sections were scanned using a micro-CT scanner. The image data was processed to estimate the cross sectional fluid distribution in XY-direction. Furthermore, each areal average Swi was calculated to investigate Swi distribution in Z-direction (direction of injection). Based on the comparison of interpreted fluid distribution, pros/cons of each technique was discussed.","PeriodicalId":10891,"journal":{"name":"Day 2 Thu, February 24, 2022","volume":"139 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-02-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Day 2 Thu, February 24, 2022","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2118/208860-ms","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In this study, we established initial water saturation (Swi) using three techniques: (1) the dynamic displacement technique, (2) the porous plate technique, and (3) the vacuum saturation technique. A unique heterogeneous carbonate reservoir rock sample (1.5-inch diameter and 3-inches long) was used repeatedly to compare the techniques without an uncertainty of different cores. After establishing Swi by each initialization technique, the cross sections were scanned using a micro-CT scanner. The image data was processed to estimate the cross sectional fluid distribution in XY-direction. Furthermore, each areal average Swi was calculated to investigate Swi distribution in Z-direction (direction of injection). Based on the comparison of interpreted fluid distribution, pros/cons of each technique was discussed.