Evaluation of physicochemical and microbiological quality of drinking water in the distribution system of Dharan, Nepal

Aasara Khatiwada, Asmita Chaudhary, Dhiren Subba Limbu, Bijaya Maharjan
{"title":"Evaluation of physicochemical and microbiological quality of drinking water in the distribution system of Dharan, Nepal","authors":"Aasara Khatiwada, Asmita Chaudhary, Dhiren Subba Limbu, Bijaya Maharjan","doi":"10.3126/hijost.v6i1.50642","DOIUrl":null,"url":null,"abstract":"Dharan has been facing drinking water-related problems for a very long time now and this research was conducted in order to determine whether the quality of water being distributed throughout the city was one of them. Hence, 31 samples were taken from the drinking water distribution system of Dharan in the spring of 2022 for evaluating the physicochemical and microbiological quality of drinking water being distributed across the sub-metropolitan city. Though public knowledge and adequate management of watershed and reservoir premises were insufficient, the physicochemical characteristics were determined to be within the National Drinking Water Quality Standards (NDWQS) for drinking water with temperatures ranging from 23.6 °C to 25.6 °C, pH 7.7 to 8.5, conductivity 38.2 to 38.7 µS/cm, Dissolved Oxygen (DO) 7.7 to 9.0 mg/L, Biological Oxygen Demand (BOD) 0.8 to 1.8 mg/L, chloride 29.82 to 34.08 mg/L, nitrite 10 mg/L and ammonia <0.5 mg/L. However, the coliform bacteria levels were significant, with the highest TCC (Total Coliform Count) being 137 CFU/100mL, the highest FCC (Fecal Coliform Count) being 85 CFU/100mL and the highest TPC (Total Plate Count) being TMTC (Too Many To Count). The water was found to be unsafe to drink without disinfection treatments. It may be necessary to carry out treatment procedures like chlorination as advised by WHO (World Health Organization) as soon as possible while also taking into account the proper application of filtration techniques for distributing safe drinking water to the residents of Dharan.","PeriodicalId":12935,"journal":{"name":"Himalayan Journal of Science and Technology","volume":"5 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Himalayan Journal of Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3126/hijost.v6i1.50642","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Dharan has been facing drinking water-related problems for a very long time now and this research was conducted in order to determine whether the quality of water being distributed throughout the city was one of them. Hence, 31 samples were taken from the drinking water distribution system of Dharan in the spring of 2022 for evaluating the physicochemical and microbiological quality of drinking water being distributed across the sub-metropolitan city. Though public knowledge and adequate management of watershed and reservoir premises were insufficient, the physicochemical characteristics were determined to be within the National Drinking Water Quality Standards (NDWQS) for drinking water with temperatures ranging from 23.6 °C to 25.6 °C, pH 7.7 to 8.5, conductivity 38.2 to 38.7 µS/cm, Dissolved Oxygen (DO) 7.7 to 9.0 mg/L, Biological Oxygen Demand (BOD) 0.8 to 1.8 mg/L, chloride 29.82 to 34.08 mg/L, nitrite 10 mg/L and ammonia <0.5 mg/L. However, the coliform bacteria levels were significant, with the highest TCC (Total Coliform Count) being 137 CFU/100mL, the highest FCC (Fecal Coliform Count) being 85 CFU/100mL and the highest TPC (Total Plate Count) being TMTC (Too Many To Count). The water was found to be unsafe to drink without disinfection treatments. It may be necessary to carry out treatment procedures like chlorination as advised by WHO (World Health Organization) as soon as possible while also taking into account the proper application of filtration techniques for distributing safe drinking water to the residents of Dharan.
尼泊尔达兰市供水系统饮用水理化及微生物质量评价
很长一段时间以来,达兰一直面临着与饮用水有关的问题,进行这项研究是为了确定整个城市分配的水的质量是否是其中之一。因此,我们于2022年春季从达兰市饮用水分配系统中采集了31个样本,用于评估分布在副大都市的饮用水的理化和微生物质量。虽然公众对流域和水库的了解和管理不足,但其理化特性符合国家饮用水质量标准(NDWQS),饮用水温度为23.6°C ~ 25.6°C, pH值为7.7 ~ 8.5,电导率为38.2 ~ 38.7µS/cm,溶解氧(DO)为7.7 ~ 9.0 mg/L,生物需氧量(BOD)为0.8 ~ 1.8 mg/L,氯化物为29.82 ~ 34.08 mg/L,亚硝酸盐为10 mg/L,氨<0.5 mg/L。大肠菌群最高TCC (Total coliform Count)为137 CFU/100mL,最高FCC (Fecal coliform Count)为85 CFU/100mL,最高TPC (Total Plate Count)为TMTC (Too Many To Count)。未经消毒处理的水是不安全的。可能有必要尽快按照世界卫生组织的建议进行氯化等处理程序,同时也要考虑到适当应用过滤技术向达兰居民分发安全饮用水。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信