UBM measured changes in anterior chamber depth following pediatric IOL surgery with optic capture

B. DeBroff, J. C. Esteban, J. Servat
{"title":"UBM measured changes in anterior chamber depth following pediatric IOL surgery with optic capture","authors":"B. DeBroff, J. C. Esteban, J. Servat","doi":"10.15406/AOVS.2018.08.00276","DOIUrl":null,"url":null,"abstract":"Submit Manuscript | http://medcraveonline.com in IOL power calculation. Anterior chamber depth determined by postoperative IOL position can lead to an error in IOL power calculation and has been shown to be one of the principal errors in IOL power calculations.7,8 The purpose of this paper is to study changes in anterior chamber depth (ACD) with Ultrasound Biomicroscopy (UBM) before and after pediatric cataract surgery with the technique of posterior curvilinear capsulorhexis with optic capture and anterior vitrectomy, and compare to the fellow eye in which no surgery or an IOL was positioned in-the-bag without capture.","PeriodicalId":90420,"journal":{"name":"Advances in ophthalmology & visual system","volume":"49 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2018-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in ophthalmology & visual system","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15406/AOVS.2018.08.00276","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Submit Manuscript | http://medcraveonline.com in IOL power calculation. Anterior chamber depth determined by postoperative IOL position can lead to an error in IOL power calculation and has been shown to be one of the principal errors in IOL power calculations.7,8 The purpose of this paper is to study changes in anterior chamber depth (ACD) with Ultrasound Biomicroscopy (UBM) before and after pediatric cataract surgery with the technique of posterior curvilinear capsulorhexis with optic capture and anterior vitrectomy, and compare to the fellow eye in which no surgery or an IOL was positioned in-the-bag without capture.
UBM测量了小儿人工晶状体手术后前房深度的变化
提交稿件| http://medcraveonline.com人工晶状体度数计算。由术后人工晶状体位置决定的前房深度可导致人工晶状体度数计算的误差,并且已被证明是人工晶状体度数计算的主要误差之一。7,8本研究的目的是利用超声生物显微镜(UBM)研究儿童白内障手术前后前房深度(ACD)的变化,并与不手术或不捕获人工晶状体放置在袋内的同侧眼进行比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信