{"title":"Annular multifrequency piezoelectric array for enhanced wideband ultrasonic response","authors":"J. Topete, T. Álvarez-Arenas","doi":"10.1109/ICSENS.2014.6984943","DOIUrl":null,"url":null,"abstract":"This paper presents the main results of a research carried out to achieve ultrasonic piezoelectric transducers with a bandwidth larger than that of present devices. The design is based on a kerfless multifrequency annular array, which is machined out of a 1-3 connectivity piezocomposite disk. The elements of the array are designed so that they present a different resonant frequency and the individual frequency bands of the elements overlap to furnish an overall response that approximate to the sum of the individual responses. A two elements array is presented: a central disk and a external ring with centre frequencies of 0.55 and 0.25 MHz, respectively. The transducer is designed for water immersion and is tested in pulse-echo. Bandwidth of the final design extends from 0.19 MHz up to 0.98 MHz, with a 6dB relative bandwidth close to 130%.","PeriodicalId":13244,"journal":{"name":"IEEE SENSORS 2014 Proceedings","volume":"115 1","pages":"102-105"},"PeriodicalIF":0.0000,"publicationDate":"2014-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE SENSORS 2014 Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENS.2014.6984943","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
This paper presents the main results of a research carried out to achieve ultrasonic piezoelectric transducers with a bandwidth larger than that of present devices. The design is based on a kerfless multifrequency annular array, which is machined out of a 1-3 connectivity piezocomposite disk. The elements of the array are designed so that they present a different resonant frequency and the individual frequency bands of the elements overlap to furnish an overall response that approximate to the sum of the individual responses. A two elements array is presented: a central disk and a external ring with centre frequencies of 0.55 and 0.25 MHz, respectively. The transducer is designed for water immersion and is tested in pulse-echo. Bandwidth of the final design extends from 0.19 MHz up to 0.98 MHz, with a 6dB relative bandwidth close to 130%.