To What Extent Does Downsampling, Compression, and Data Scarcity Impact Renal Image Analysis?

Can Peng, Kun Zhao, A. Wiliem, Teng Zhang, Peter Hobson, A. Jennings, B. Lovell
{"title":"To What Extent Does Downsampling, Compression, and Data Scarcity Impact Renal Image Analysis?","authors":"Can Peng, Kun Zhao, A. Wiliem, Teng Zhang, Peter Hobson, A. Jennings, B. Lovell","doi":"10.1109/DICTA47822.2019.8945813","DOIUrl":null,"url":null,"abstract":"The condition of the Glomeruli, or filter sacks, in renal Direct Immunofluorescence (DIF) specimens is a critical indicator for diagnosing kidney diseases. A digital pathology system which digitizes a glass histology slide into a Whole Slide Image (WSI) and then automatically detects and zooms in on the glomeruli with a higher magnification objective will be extremely helpful for pathologists. In this paper, using glomerulus detection as the study case, we provide analysis and observations on several important issues to help with the development of Computer Aided Diagnostic (CAD) systems to process WSIs. Large image resolution, large file size, and data scarcity are always challenging to deal with. To this end, we first examine image downsampling rates in terms of their effect on detection accuracy. Second, we examine the impact of image compression. Third, we examine the relationship between the size of the training set and detection accuracy. To understand the above issues, experiments are performed on the state-of-the-art detectors: Faster R-CNN, R-FCN, Mask R-CNN and SSD. Critical findings are observed: (1) The best balance between detection accuracy, detection speed and file size is achieved at 8 times downsampling captured with a 40 χ objective; (2) compression which reduces the file size dramatically, does not necessarily have an adverse effect on overall accuracy; (3) reducing the amount of training data to some extents causes a drop in precision but has a negligible impact on the recall; (4) in most cases, Faster R-CNN achieves the best accuracy in the glomerulus detection task. We show that the image file size of 40 χ WSI images can be reduced by a factor of over 6000 with negligible loss of glomerulus detection accuracy.","PeriodicalId":6696,"journal":{"name":"2019 Digital Image Computing: Techniques and Applications (DICTA)","volume":"36 1","pages":"1-8"},"PeriodicalIF":0.0000,"publicationDate":"2019-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 Digital Image Computing: Techniques and Applications (DICTA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DICTA47822.2019.8945813","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

The condition of the Glomeruli, or filter sacks, in renal Direct Immunofluorescence (DIF) specimens is a critical indicator for diagnosing kidney diseases. A digital pathology system which digitizes a glass histology slide into a Whole Slide Image (WSI) and then automatically detects and zooms in on the glomeruli with a higher magnification objective will be extremely helpful for pathologists. In this paper, using glomerulus detection as the study case, we provide analysis and observations on several important issues to help with the development of Computer Aided Diagnostic (CAD) systems to process WSIs. Large image resolution, large file size, and data scarcity are always challenging to deal with. To this end, we first examine image downsampling rates in terms of their effect on detection accuracy. Second, we examine the impact of image compression. Third, we examine the relationship between the size of the training set and detection accuracy. To understand the above issues, experiments are performed on the state-of-the-art detectors: Faster R-CNN, R-FCN, Mask R-CNN and SSD. Critical findings are observed: (1) The best balance between detection accuracy, detection speed and file size is achieved at 8 times downsampling captured with a 40 χ objective; (2) compression which reduces the file size dramatically, does not necessarily have an adverse effect on overall accuracy; (3) reducing the amount of training data to some extents causes a drop in precision but has a negligible impact on the recall; (4) in most cases, Faster R-CNN achieves the best accuracy in the glomerulus detection task. We show that the image file size of 40 χ WSI images can be reduced by a factor of over 6000 with negligible loss of glomerulus detection accuracy.
降采样、压缩和数据稀缺性在多大程度上影响肾脏图像分析?
肾直接免疫荧光(DIF)标本中肾小球或滤袋的状况是诊断肾脏疾病的重要指标。数字化病理系统将玻璃组织切片数字化为全切片图像(WSI),然后用更高的放大镜自动检测和放大肾小球,这对病理学家来说是非常有帮助的。本文以肾小球检测为研究案例,对几个重要问题进行分析和观察,以帮助开发计算机辅助诊断(CAD)系统来处理wsi。大图像分辨率、大文件大小和数据稀缺总是难以处理的问题。为此,我们首先检查图像降采样率对检测精度的影响。其次,我们研究了图像压缩的影响。第三,我们检验了训练集的大小和检测精度之间的关系。为了了解上述问题,在最先进的探测器上进行了实验:Faster R-CNN, R-FCN, Mask R-CNN和SSD。观察到的关键发现:(1)检测精度,检测速度和文件大小之间的最佳平衡在40 χ物镜捕获的8次下采样时实现;(2)压缩大大减少了文件大小,并不一定对整体精度产生不利影响;(3)在一定程度上减少训练数据量会导致准确率下降,但对召回率的影响可以忽略不计;(4)大多数情况下,Faster R-CNN在肾小球检测任务中准确率最高。我们表明,40 χ WSI图像的图像文件大小可以减少6000倍以上,肾小球检测精度的损失可以忽略不计。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书