{"title":"Spectrofluorometric determination of L-tryptophan after preconcentration using multi-walled carbon nanotubes","authors":"E. Zolfonoun","doi":"10.24200/AMECJ.V2.I01.43","DOIUrl":null,"url":null,"abstract":"A solid-phase extraction method based on multi-walled carbon nanotubes (MWCNTs) was applied for the preconcentration of L-tryptophan prior to its spectrofluorometric determination. Due to the high surface area of MWCNTs, satisfactory concentration factor and extraction recovery can be achieved with only 10 mg MWCNTs in 5 min. The effects of pH, sorbent amount, eluent type and time on the recovery of the analyte were investigated. Under the optimum conditions, the detection limit for L-tryptophan was 8.9 ng mL−1. The precision of the method, evaluated as the relative standard deviation obtained by analyzing of 10 replicates, was 2.6%. The practical applicability of the developed method was examined using wheat and barley samples.","PeriodicalId":7797,"journal":{"name":"Analytical Methods in Environmental Chemistry Journal","volume":"184 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Methods in Environmental Chemistry Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24200/AMECJ.V2.I01.43","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

A solid-phase extraction method based on multi-walled carbon nanotubes (MWCNTs) was applied for the preconcentration of L-tryptophan prior to its spectrofluorometric determination. Due to the high surface area of MWCNTs, satisfactory concentration factor and extraction recovery can be achieved with only 10 mg MWCNTs in 5 min. The effects of pH, sorbent amount, eluent type and time on the recovery of the analyte were investigated. Under the optimum conditions, the detection limit for L-tryptophan was 8.9 ng mL−1. The precision of the method, evaluated as the relative standard deviation obtained by analyzing of 10 replicates, was 2.6%. The practical applicability of the developed method was examined using wheat and barley samples.
多壁碳纳米管预浓缩后荧光光谱法测定l -色氨酸
采用基于多壁碳纳米管(MWCNTs)的固相萃取法对l -色氨酸进行预富集,然后进行荧光光谱测定。由于MWCNTs的高表面积,仅需10 mg MWCNTs即可在5 min内获得满意的浓度因子和萃取回收率。研究了pH、吸附剂用量、洗脱液类型和时间对分析物回收率的影响。在最佳条件下,l -色氨酸的检出限为8.9 ng mL−1。通过分析10个重复得到的相对标准偏差,该方法的精密度为2.6%。用小麦和大麦样品检验了该方法的实用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信