Mapping of aquifer hydraulic properties in Ogbeje and Umeghe in Abraka, Delta State Nigeria: insights from geophysical and hydrogeological methods

Merrious Oviri Ofomola, Misan Tony Eyituoyo, Ochuko Anomohanran
{"title":"Mapping of aquifer hydraulic properties in Ogbeje and Umeghe in Abraka, Delta State Nigeria: insights from geophysical and hydrogeological methods","authors":"Merrious Oviri Ofomola, Misan Tony Eyituoyo, Ochuko Anomohanran","doi":"10.47253/jtrss.v10i1.896","DOIUrl":null,"url":null,"abstract":"Vertical Electrical Sounding (VES), Pumping test, well logging and grain size analysis were conducted with the aim of studying the subsurface geophysical formation in order to determine aquifer characteristics such as hydraulic conductivity, transmissivity and other parameters for groundwater exploration purposes around Ogbeje and Umeghe, Abraka Delta State. Nine (9) VES stations were occupied and the results obtained from the computer iterations suggest 4 to 5 geoelectric layers. The aquiferous layers wwerefound at a depth ranging from 20.0 m – 38.3 m with resistivity ranging from 2200 ?m to 8500 ?m and thickness varying between 6.7 and 20.0 m. The VES study reveals the possibility of having a maximum drill depth the o water table of about 38 m. The results obtained from the pumping test and well logginwereas used to estimate the transmissivity value of T = 0.0722 m2/min, storativity S = 0.00063, specific capacity of the well = 0.39 m2/min and hydraulic conductivity, K= 8.5 m/day while the result from the grain size analysis gave hydraulic conductivity as Kmin= 12.96 m/d to Kmax = 26.96 m/d respectively. Thus, these results indicate that the aquifer is capable of proda ucing sufficient amount of water for both domestic and industrial purposes for the people in the area. \n","PeriodicalId":17457,"journal":{"name":"Journal of Tropical Resources and Sustainable Science (JTRSS)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Tropical Resources and Sustainable Science (JTRSS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47253/jtrss.v10i1.896","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Vertical Electrical Sounding (VES), Pumping test, well logging and grain size analysis were conducted with the aim of studying the subsurface geophysical formation in order to determine aquifer characteristics such as hydraulic conductivity, transmissivity and other parameters for groundwater exploration purposes around Ogbeje and Umeghe, Abraka Delta State. Nine (9) VES stations were occupied and the results obtained from the computer iterations suggest 4 to 5 geoelectric layers. The aquiferous layers wwerefound at a depth ranging from 20.0 m – 38.3 m with resistivity ranging from 2200 ?m to 8500 ?m and thickness varying between 6.7 and 20.0 m. The VES study reveals the possibility of having a maximum drill depth the o water table of about 38 m. The results obtained from the pumping test and well logginwereas used to estimate the transmissivity value of T = 0.0722 m2/min, storativity S = 0.00063, specific capacity of the well = 0.39 m2/min and hydraulic conductivity, K= 8.5 m/day while the result from the grain size analysis gave hydraulic conductivity as Kmin= 12.96 m/d to Kmax = 26.96 m/d respectively. Thus, these results indicate that the aquifer is capable of proda ucing sufficient amount of water for both domestic and industrial purposes for the people in the area.
尼日利亚三角洲州ababaka Ogbeje和Umeghe含水层水力特性制图:来自地球物理和水文地质方法的见解
通过垂直电测深(VES)、抽水试验、测井和粒度分析,研究地下地球物理地层,确定含水层特征,如导电性、透射率等参数,为Abraka三角洲州Ogbeje和Umeghe地区的地下水勘探提供依据。共占用了9个测点,计算机迭代结果显示地电层数为4 ~ 5层。含水层分布深度为20.0 ~ 38.3 m,电阻率为2200 ~ 8500 m,厚度为6.7 ~ 20.0 m。VES研究表明,在地下水位约为38米时,最大钻深的可能性。根据泵送试验和测井结果,估算出透光率T = 0.0722 m2/min,储水率S = 0.00063,井比容= 0.39 m2/min,水力导率K= 8.5 m/d,而粒度分析结果得出的水力导率Kmin= 12.96 m/d ~ Kmax = 26.96 m/d。因此,这些结果表明,该含水层能够为该地区人民提供足够的家庭和工业用水。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信