PhD, FBCO, DCLP Marion H. Edwards, BOptom Pauline Cho
{"title":"A new, hand-held keratometer: comparison of theNidek KM-500 auto keratometer with the B&L keratometer and the topcon RK-3000A keratometer","authors":"PhD, FBCO, DCLP Marion H. Edwards, BOptom Pauline Cho","doi":"10.1016/S0141-7037(96)80032-2","DOIUrl":null,"url":null,"abstract":"<div><p>The Nidek KM-500 is a recently introduced hand-held automatic keratometer. If the accuracy and reliability of thisinstrument are good then it offers a number of benefits to contact lens practitioners and other clinicians. This study investigated the repeatability and reproducibility of readings taken using the hand-held Nidek KM-500, the Topcon RK-3000A and the Bausch & Lomb keratometer. The Nidek KM-500 was found to be reliable when used according to the manufacturer's instructions and the readings equated well with those obtained with the table-mounted Topcon KR-3000A. The repeatability of the Bausch & Lomb keratometer can be improved by taking the mean of three readings. Clinicians should consider conducting a simple repeatability study of the keratometer used in their own practice. The results may help to pinpoint a weakness in technique when using a non-automated instrument, and will establish the criterion for a true change in corneal radius.</p></div>","PeriodicalId":100842,"journal":{"name":"Journal of The British Contact Lens Association","volume":"19 2","pages":"Pages 45-48"},"PeriodicalIF":0.0000,"publicationDate":"1996-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0141-7037(96)80032-2","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of The British Contact Lens Association","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0141703796800322","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8
Abstract
The Nidek KM-500 is a recently introduced hand-held automatic keratometer. If the accuracy and reliability of thisinstrument are good then it offers a number of benefits to contact lens practitioners and other clinicians. This study investigated the repeatability and reproducibility of readings taken using the hand-held Nidek KM-500, the Topcon RK-3000A and the Bausch & Lomb keratometer. The Nidek KM-500 was found to be reliable when used according to the manufacturer's instructions and the readings equated well with those obtained with the table-mounted Topcon KR-3000A. The repeatability of the Bausch & Lomb keratometer can be improved by taking the mean of three readings. Clinicians should consider conducting a simple repeatability study of the keratometer used in their own practice. The results may help to pinpoint a weakness in technique when using a non-automated instrument, and will establish the criterion for a true change in corneal radius.