Optimization of injected radiotracer volume for flow rate measurement in closed conduits

M. Pavlovic, Marijana Pantovic-Pavlovic, P. Bartl, J. Stevanovic, B. Radak
{"title":"Optimization of injected radiotracer volume for flow rate measurement in closed conduits","authors":"M. Pavlovic, Marijana Pantovic-Pavlovic, P. Bartl, J. Stevanovic, B. Radak","doi":"10.2298/HEMIND20050325P","DOIUrl":null,"url":null,"abstract":"In chemical processes it is essential that the flow in the process is accurately defined. Fluid velocity measurements are important for fluid flow quality performance in flow systems. This study focuses on determination of the volumetric flow rate and its standard (relative) deviation for calibration of conventional flow meters by using a radiotracer approach. The measurements for flow meter calibration were performed at a pilot-scale flow rig using Technetium-99 m (99mTc) as a radiotracer in the form of pertechnetate ion (99mTcO4-). The measured data were analyzed, and precision of the experimental setup was investigated under two different approaches ? IAEA?s RTD software and sum approximation of raw data. For the first time, the variation of standard deviation of calculated flow rate with the injection volume and activity of the radiotracer was determined. Plug flow with axial dispersion was used to simulate the measured RTD curves and investigate the flow dynamics of the flowing water. The results of the study have shown the possibility of in situ calibration of flow meters with a relative error lower than 1 %. They also revealed a slight dependency of the precision of output results on the injection volume as well as similar results for manual and specialized RTD software data processing.","PeriodicalId":9933,"journal":{"name":"Chemical Industry","volume":"53 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chemical Industry","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.2298/HEMIND20050325P","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

In chemical processes it is essential that the flow in the process is accurately defined. Fluid velocity measurements are important for fluid flow quality performance in flow systems. This study focuses on determination of the volumetric flow rate and its standard (relative) deviation for calibration of conventional flow meters by using a radiotracer approach. The measurements for flow meter calibration were performed at a pilot-scale flow rig using Technetium-99 m (99mTc) as a radiotracer in the form of pertechnetate ion (99mTcO4-). The measured data were analyzed, and precision of the experimental setup was investigated under two different approaches ? IAEA?s RTD software and sum approximation of raw data. For the first time, the variation of standard deviation of calculated flow rate with the injection volume and activity of the radiotracer was determined. Plug flow with axial dispersion was used to simulate the measured RTD curves and investigate the flow dynamics of the flowing water. The results of the study have shown the possibility of in situ calibration of flow meters with a relative error lower than 1 %. They also revealed a slight dependency of the precision of output results on the injection volume as well as similar results for manual and specialized RTD software data processing.
封闭管道流量测量中注入示踪剂体积的优化
在化学过程中,精确地定义过程中的流动是至关重要的。在流动系统中,流体速度测量对流体流动质量性能具有重要意义。本研究的重点是利用放射性示踪剂方法确定常规流量计的体积流量及其标准(相对)偏差。流量计校准的测量是在一个中试规模的流量钻机上进行的,使用锝-99 (99mTc)作为高锝酸盐离子(99mTcO4-)形式的放射性示踪剂。对测量数据进行了分析,并在两种不同的方法下对实验装置的精度进行了研究。国际原子能机构?s RTD软件和原始数据的求和近似。首次确定了计算流量的标准差随注入量和放射性示踪剂活度的变化规律。采用轴向弥散塞流模拟实测RTD曲线,研究了流动水的流动动力学。研究结果表明,流量计现场标定的相对误差小于1%是可能的。他们还揭示了输出结果的精度对注入量的轻微依赖,以及手动和专门的RTD软件数据处理的类似结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信