Reliability of Using Kinovea Program in Measuring Dominant Wrist Joint Range of Motion

Reham M. Abd El-Raheem, R. Kamel, Mohammad Ali
{"title":"Reliability of Using Kinovea Program in Measuring Dominant Wrist Joint Range of Motion","authors":"Reham M. Abd El-Raheem, R. Kamel, Mohammad Ali","doi":"10.3923/TASR.2015.224.230","DOIUrl":null,"url":null,"abstract":"The purposes of this study were to investigate the intra-rater and inter-rater reliabilities of the Kinovea software program for the measurement of dominant wrist joint range of motion in healthy participants. One hundred normal subjects with age ranged from 20-35 from both sex. Interrater reliability of Kinovea program tested by participation of three different raters and the Intra-rater tested by one rater measured wrist joint ROM three time using digital camera and software device in order to measure the wrist flexion, extension, abduction and adduction range of motion using the Kinovea software program. Results revealed no statistical significant difference in both inter-rater and intra-rater reliability after using Kinovea software in the measurement of wrist joint range of motion. The results of the present study indicated that the Kinovea software program was reliable in both inter and intra-rater reliability for wrist joint ROM measurement.","PeriodicalId":23261,"journal":{"name":"Trends in Applied Sciences Research","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2015-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"25","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Trends in Applied Sciences Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3923/TASR.2015.224.230","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 25

Abstract

The purposes of this study were to investigate the intra-rater and inter-rater reliabilities of the Kinovea software program for the measurement of dominant wrist joint range of motion in healthy participants. One hundred normal subjects with age ranged from 20-35 from both sex. Interrater reliability of Kinovea program tested by participation of three different raters and the Intra-rater tested by one rater measured wrist joint ROM three time using digital camera and software device in order to measure the wrist flexion, extension, abduction and adduction range of motion using the Kinovea software program. Results revealed no statistical significant difference in both inter-rater and intra-rater reliability after using Kinovea software in the measurement of wrist joint range of motion. The results of the present study indicated that the Kinovea software program was reliable in both inter and intra-rater reliability for wrist joint ROM measurement.
使用Kinovea程序测量手腕主要关节活动范围的可靠性
本研究的目的是调查Kinovea软件程序用于测量健康参与者的主要手腕关节活动范围的内部和内部可靠性。100名正常受试者,年龄在20-35岁之间,男女不限。采用Kinovea软件程序对腕关节屈曲、伸、外展和内收活动范围进行测量,采用数码相机和软件装置对Kinovea软件程序进行三次测量腕关节ROM,采用三种不同的评分者参与Kinovea程序的评分者之间的可靠性测试和一种评分者之间的可靠性测试。结果显示,在使用Kinovea软件测量腕关节活动范围后,评分者间和评分者内的可靠性均无统计学差异。本研究结果表明,Kinovea软件程序在腕关节ROM测量的内部和内部可靠性方面都是可靠的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信