The relationship between time of re-tightening and preload loss of abutment screws for two different implant designs: an in-vitro study.

G. Varvara, B. Sinjari, S. Caputi, A. Scarano, M. Piattelli
{"title":"The relationship between time of re-tightening and preload loss of abutment screws for two different implant designs: an in-vitro study.","authors":"G. Varvara, B. Sinjari, S. Caputi, A. Scarano, M. Piattelli","doi":"10.1563/aaid-joi-D-18-00138","DOIUrl":null,"url":null,"abstract":"The loosening of an abutment screw is one of the most frequent complications in implant-prosthetic rehabilitation, especially for single crown cemented prostheses. This complication is due to several mechanical factors, including: type of connection, abutment-screw geometry, settling effects, and cyclical load. The purpose of the present in-vitro study was to compare and associate different times of re-tightening with reductions in preload losses. We evaluated 40 internal hexagon dental implants and 40 external hexagon dental implants, with their related abutment screws. The implants were embedded in acrylic resin in cylindrical polyvinyl chloride tubes (diameter, 26 mm; height, 20 mm). The abutments were fixed to the implants with screws to an initial torque of 35 Ncm using a digital torque meter with decimal precision. The two different types of connection were randomly divided in four subgroups of 10 samples each. One subgroup was used as control. The test groups underwent re-tightening to the same initial torque at increasing times from initial torque application for tightening of the abutment screws, to their re-tightening at 2 min, 5 min, and 10 min. The re-tightening time of 2 min shows significantly reduced preload loss. Randomized clinical trials are strongly required to provide clinicians with a beneficial standardized protocol of re-tightening that can be applied in routine clinical practice.","PeriodicalId":77634,"journal":{"name":"The International journal of oral implantology : implantologist","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of oral implantology : implantologist","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1563/aaid-joi-D-18-00138","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

The loosening of an abutment screw is one of the most frequent complications in implant-prosthetic rehabilitation, especially for single crown cemented prostheses. This complication is due to several mechanical factors, including: type of connection, abutment-screw geometry, settling effects, and cyclical load. The purpose of the present in-vitro study was to compare and associate different times of re-tightening with reductions in preload losses. We evaluated 40 internal hexagon dental implants and 40 external hexagon dental implants, with their related abutment screws. The implants were embedded in acrylic resin in cylindrical polyvinyl chloride tubes (diameter, 26 mm; height, 20 mm). The abutments were fixed to the implants with screws to an initial torque of 35 Ncm using a digital torque meter with decimal precision. The two different types of connection were randomly divided in four subgroups of 10 samples each. One subgroup was used as control. The test groups underwent re-tightening to the same initial torque at increasing times from initial torque application for tightening of the abutment screws, to their re-tightening at 2 min, 5 min, and 10 min. The re-tightening time of 2 min shows significantly reduced preload loss. Randomized clinical trials are strongly required to provide clinicians with a beneficial standardized protocol of re-tightening that can be applied in routine clinical practice.
两种不同种植体设计的基牙螺钉再拧紧时间与预载荷损失的关系:一项体外研究。
基牙螺钉松动是种植体修复中最常见的并发症之一,尤其是单冠骨水泥修复体。这种复杂性是由几个机械因素造成的,包括:连接类型、基台螺钉的几何形状、沉降效应和周期性载荷。本体外研究的目的是比较和关联不同时间的重新拧紧与减少预负荷损失。我们评估了40个内六边形种植体和40个外六边形种植体及其相关的基牙螺钉。植入物用丙烯酸树脂包埋在圆柱形聚氯乙烯管中(直径26 mm;高度,20毫米)。使用十进制精度的数字扭矩计将基台用螺钉固定在种植体上,初始扭矩为35 Ncm。这两种不同类型的连接被随机分为四组,每组10个样本。其中一个亚组作为对照。试验组对相同的初始扭矩进行重新紧固,从初始扭矩施加到拧紧基台螺钉,分别在2分钟、5分钟和10分钟进行重新紧固。2分钟的重新紧固时间显着减少了预紧损失。迫切需要随机临床试验,为临床医生提供可用于常规临床实践的有益的标准化再收紧方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书