Covering the Implant Prosthesis Screw Access Hole: A Biological Approach to Material Selection and Technique.

Todd R. Schoenbaum, C. Wadhwani, R. Stevenson
{"title":"Covering the Implant Prosthesis Screw Access Hole: A Biological Approach to Material Selection and Technique.","authors":"Todd R. Schoenbaum, C. Wadhwani, R. Stevenson","doi":"10.1563/aaid-joi-D-16-00119","DOIUrl":null,"url":null,"abstract":"W ith implant treatment in the esthetic zone, it is a constant endeavor to maintain and increase the volume of peri-implant tissues. Many recent developments in implant and abutment design have this as the primary goal. Thus we have seen the evolution and creation of ‘‘platform switch’’ abutments, narrowed abutment diameters, and conical implant connections—all in an effort to maximize the volume of the peri-implant bone and soft tissues. The conical connection in particular was developed with the aim of maximizing the integrity of the abutment– implant connection and thus reducing movement, decreasing peri-implant bone stress, and minimizing leakage of the contents inside the abutment into the delicate zone where bone, connective tissue, implant, and abutment all merge (Figure 1). This concept is sound and it does appear to reduce leakage into the peri-implant tissues, but it does not eliminate leakage. This is a problem that worsens over time with repeated loading. The ‘‘platform switch’’ design has mostly (but not entirely), proven to better maintain bone levels than abutments that flare directly from the head of the implant. Multiple finite element analyses have shown that the conical connection may serve to significantly reduce the stresses on the peri-implant crestal bone. It appears that the mechanical integrity of the conical connection provides a biologic benefit even outside the implant itself. The reason for the success seen with platform switch implants appears to be twofold: First, the nonintegrating abutment components are more narrow and thus further away from the bone allowing more space for the necessary biologic width. When nonintegrating components encroach upon this space, the bone remodels laterally and apically to create the necessary biologic space. Secondly, the platform switch design moves the implant–abutment junction (IAJ) away from the bone, and thus moves the inflammatory cell infiltrate coming from inside the implant / abutment and exiting at the IAJ further away from the crestal bone. Much histological study has been made into the biologic environment adjacent to the IAJ, and it has been well established that bone is maintained at a more coronal position when leakage is minimized by use of conical connections, and when the leakage that does occur is moved further away from the bone by use of platform switch abutments. Recent short-term data suggest that the conical connection and minimizing leakage at the IAJ is the more important factor in limiting bone loss. Based on these concepts, it is evident that the contents inside the implant/ abutment directly, and negatively, affect the peri-implant bone position. Leakage from the IAJ cannot be eliminated, but efforts should be made by the clinician to minimize it. It is clear that the contents of the implant/abutment negatively affect the peri-implant bone, and that they will leak from the IAJ. Thus, what is put into the abutment to cover the screw can have a significant effect. According to a 2008 survey, 59% of prosthodontic residency directors and 77% of restorative department chairpersons in the United States use cotton pellets to cover the screw access opening under the definitive restoration. The use of cotton is an adaptation of the method used to temporarily fill the access for endodontically treated teeth, though it appears to be falling out of vogue for this purpose as well. It should be noted that cotton was never intended for use under a definitive restoration. The problem with the use of cotton is that the internal aspect of most implants and implant abutments are hollow, whereas the connection at the IAJ between them is prone to leakage. This creates a 358C, mostly oxygen-free, hollow tube filled with saliva, oral flora, and nutrients—an environment ripe for the proliferation of anaerobic bacteria. As the patient functions on the implant, the IAJ continues to flex and wear, pumping saliva, nutrients and oral flora into the implant chamber from the peri-implant area (not the screw access hole). As the anaerobic bacteria proliferate and the IAJ continues to flex and leak, the anaerobic byproducts are pumped out of the implant at the IAJ and directly into the peri-implant tissues. Covering the screw with cotton, in particular, appears to be problematic because it is an open, organic, scaffold-like structure (Figure 2). These properties provide pathogenic oral flora an ideal substrate upon which to flourish and which likely increases the volume and potency of the inflammatory cell infiltrate. Additionally, cotton has been shown to allow the most leakage into the implant, when compared in vitro to gutta-percha, silicone plugs, and polyvinyl siloxane (PVS) impression materials. The seal created by polytetrafluoroethylene (PTFE) tape has been shown to be effective in sealing endodontically treated teeth and in implant abutments when compared with cotton. Ultimately, it appears that the 1 Section of Restorative Dentistry, University of California-Los Angeles School of Dentistry, Los Angeles, CA, USA. 2 Department of Restorative Dentistry, Loma Linda University School of Dentistry, Loma Linda, CA, USA. 3 Private practice limited to prosthodontics, Bellevue, WA, USA. * Corresponding author, e-mail: tschoenbaum@dentistry.ucla.edu DOI: 10.1563/aaid-joi-D-16-00119","PeriodicalId":77634,"journal":{"name":"The International journal of oral implantology : implantologist","volume":"11 1","pages":"39-44"},"PeriodicalIF":0.0000,"publicationDate":"2017-02-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of oral implantology : implantologist","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1563/aaid-joi-D-16-00119","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

W ith implant treatment in the esthetic zone, it is a constant endeavor to maintain and increase the volume of peri-implant tissues. Many recent developments in implant and abutment design have this as the primary goal. Thus we have seen the evolution and creation of ‘‘platform switch’’ abutments, narrowed abutment diameters, and conical implant connections—all in an effort to maximize the volume of the peri-implant bone and soft tissues. The conical connection in particular was developed with the aim of maximizing the integrity of the abutment– implant connection and thus reducing movement, decreasing peri-implant bone stress, and minimizing leakage of the contents inside the abutment into the delicate zone where bone, connective tissue, implant, and abutment all merge (Figure 1). This concept is sound and it does appear to reduce leakage into the peri-implant tissues, but it does not eliminate leakage. This is a problem that worsens over time with repeated loading. The ‘‘platform switch’’ design has mostly (but not entirely), proven to better maintain bone levels than abutments that flare directly from the head of the implant. Multiple finite element analyses have shown that the conical connection may serve to significantly reduce the stresses on the peri-implant crestal bone. It appears that the mechanical integrity of the conical connection provides a biologic benefit even outside the implant itself. The reason for the success seen with platform switch implants appears to be twofold: First, the nonintegrating abutment components are more narrow and thus further away from the bone allowing more space for the necessary biologic width. When nonintegrating components encroach upon this space, the bone remodels laterally and apically to create the necessary biologic space. Secondly, the platform switch design moves the implant–abutment junction (IAJ) away from the bone, and thus moves the inflammatory cell infiltrate coming from inside the implant / abutment and exiting at the IAJ further away from the crestal bone. Much histological study has been made into the biologic environment adjacent to the IAJ, and it has been well established that bone is maintained at a more coronal position when leakage is minimized by use of conical connections, and when the leakage that does occur is moved further away from the bone by use of platform switch abutments. Recent short-term data suggest that the conical connection and minimizing leakage at the IAJ is the more important factor in limiting bone loss. Based on these concepts, it is evident that the contents inside the implant/ abutment directly, and negatively, affect the peri-implant bone position. Leakage from the IAJ cannot be eliminated, but efforts should be made by the clinician to minimize it. It is clear that the contents of the implant/abutment negatively affect the peri-implant bone, and that they will leak from the IAJ. Thus, what is put into the abutment to cover the screw can have a significant effect. According to a 2008 survey, 59% of prosthodontic residency directors and 77% of restorative department chairpersons in the United States use cotton pellets to cover the screw access opening under the definitive restoration. The use of cotton is an adaptation of the method used to temporarily fill the access for endodontically treated teeth, though it appears to be falling out of vogue for this purpose as well. It should be noted that cotton was never intended for use under a definitive restoration. The problem with the use of cotton is that the internal aspect of most implants and implant abutments are hollow, whereas the connection at the IAJ between them is prone to leakage. This creates a 358C, mostly oxygen-free, hollow tube filled with saliva, oral flora, and nutrients—an environment ripe for the proliferation of anaerobic bacteria. As the patient functions on the implant, the IAJ continues to flex and wear, pumping saliva, nutrients and oral flora into the implant chamber from the peri-implant area (not the screw access hole). As the anaerobic bacteria proliferate and the IAJ continues to flex and leak, the anaerobic byproducts are pumped out of the implant at the IAJ and directly into the peri-implant tissues. Covering the screw with cotton, in particular, appears to be problematic because it is an open, organic, scaffold-like structure (Figure 2). These properties provide pathogenic oral flora an ideal substrate upon which to flourish and which likely increases the volume and potency of the inflammatory cell infiltrate. Additionally, cotton has been shown to allow the most leakage into the implant, when compared in vitro to gutta-percha, silicone plugs, and polyvinyl siloxane (PVS) impression materials. The seal created by polytetrafluoroethylene (PTFE) tape has been shown to be effective in sealing endodontically treated teeth and in implant abutments when compared with cotton. Ultimately, it appears that the 1 Section of Restorative Dentistry, University of California-Los Angeles School of Dentistry, Los Angeles, CA, USA. 2 Department of Restorative Dentistry, Loma Linda University School of Dentistry, Loma Linda, CA, USA. 3 Private practice limited to prosthodontics, Bellevue, WA, USA. * Corresponding author, e-mail: tschoenbaum@dentistry.ucla.edu DOI: 10.1563/aaid-joi-D-16-00119
覆盖种植体假体螺钉通路孔:材料选择和技术的生物学方法。
在审美区进行种植体治疗时,需要不断努力维持和增加种植体周围组织的体积。许多种植体和基台设计的最新发展都将此作为主要目标。因此,我们看到了“平台开关”基台的发展和创造,缩小了基台直径,锥形种植体连接-所有这些都是为了最大限度地增加种植体周围骨和软组织的体积。尤其是圆锥连接,其目的是最大限度地提高基牙-种植体连接的完整性,从而减少运动,减少种植体周围的骨应力,并最大限度地减少基牙内的内容物渗漏到骨、结缔组织、种植体和基牙融合的脆弱区域(图1)。这个概念是合理的,它确实减少了渗漏到种植体周围组织,但它并不能消除渗漏。随着时间的推移,这个问题会随着反复加载而恶化。“平台切换”设计大部分(但不是全部)被证明比直接从种植体头部伸出的基台更好地维持骨水平。多次有限元分析表明,锥形连接可以显著减少种植体周围嵴骨的应力。看来,锥形连接的机械完整性甚至在种植体本身之外也提供了生物学上的益处。平台开关种植体成功的原因似乎有两个方面:首先,非整合基台组件更窄,因此远离骨骼,为必要的生物宽度提供更多空间。当非整合成分侵入这个空间时,骨向外侧和顶端重塑以创造必要的生物空间。其次,平台开关设计使种植体-基台连接(IAJ)远离骨,从而使来自种植体/基台内部并在IAJ处存在的炎症细胞浸润远离冠骨。对IAJ附近的生物环境进行了大量的组织学研究,并且已经确定,当使用锥形连接将泄漏最小化时,骨保持在更冠状的位置,当确实发生泄漏时,通过使用平台开关基台将其移离骨。最近的短期数据表明,锥形连接和尽量减少IAJ的渗漏是限制骨质流失的更重要因素。基于这些概念,很明显种植体/基台内的内容物直接且负面地影响种植体周围的骨位置。IAJ的渗漏无法消除,但临床医生应努力将其最小化。很明显,种植体/基台的内容物会对种植体周围骨产生负面影响,并且会从IAJ中泄漏。因此,在基台放置什么来覆盖螺钉可以有显著的效果。根据2008年的一项调查,美国59%的义齿住院医师主任和77%的修复科主任在最终修复下使用棉花球覆盖螺钉通道开口。棉花的使用是一种适应的方法,用于暂时填充根管治疗牙齿的通道,尽管它似乎也不再流行于此目的。应该指出的是,棉花从未打算在最终恢复下使用。使用棉花的问题是,大多数种植体和种植基台的内部是中空的,而它们之间的IAJ连接容易泄漏。这就产生了一个358摄氏度的、基本上无氧的中空管,里面充满了唾液、口腔菌群和营养物质——这是厌氧细菌增殖的成熟环境。当患者在种植体上活动时,IAJ继续弯曲和磨损,将唾液、营养物质和口腔菌群从种植体周围区域(而不是螺钉进入孔)泵入种植腔。随着厌氧细菌的增殖和IAJ继续弯曲和泄漏,厌氧副产物从IAJ处的植入物中泵出,直接进入植入物周围组织。特别是用棉花覆盖螺钉,似乎是有问题的,因为它是一个开放的、有机的、支架状的结构(图2)。这些特性为致病性口腔菌群提供了一个理想的底物,可以在其上繁殖,并可能增加炎症细胞浸润的体积和效力。此外,与杜仲胶、硅胶塞和聚乙烯醇硅氧烷(PVS)压模材料相比,棉花被证明是最容易渗入植入物的材料。与棉花相比,聚四氟乙烯(PTFE)胶带所产生的密封在密封髓内治疗过的牙齿和种植体基台方面已被证明是有效的。 最终,美国加州大学洛杉矶分校牙科学院修复牙科1科。2美国洛马林达大学牙科学院口腔修复系,加州洛马林达;3私人执业,仅限于修复,Bellevue, WA, USA。*通讯作者,e-mail: tschoenbaum@dentistry.ucla.edu DOI: 10.1563/ aiaid -jo - d- 16-00119
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书