Sujet Phodapol, Tachadol Suthisomboon, P. Kosanunt, Ravipas Vongasemjit, P. Janbanjong, P. Manoonpong
{"title":"Morphological Adaptation for Speed Control of Pipeline Inspection Gauges MC-PIG","authors":"Sujet Phodapol, Tachadol Suthisomboon, P. Kosanunt, Ravipas Vongasemjit, P. Janbanjong, P. Manoonpong","doi":"10.2118/207403-ms","DOIUrl":null,"url":null,"abstract":"\n Passive and active hybrid pipeline inspection gauges (PIGs) have been used for in-pipe inspection. While a passive PIG cannot control its speed, the hybrid version can achieve this by using an integrated valve specifically designed and embedded in the PIG. This study proposes a generic new method for speed adaptation in PIGs (called MC-PIG) by introducing a generic, modular, controllable, external valve unit add-on for attaching to existing conventional (passive) PIGs with minimal change. The MC-PIG method is based on the principle of morphological computation with closed-loop control. It is achieved by regulating/computing the PIG's morphology (i.e., a modular rotary valve unit add-on) to control bypass flow. Adjustment of the valve angle can affect the flow rate passing through the PIG, resulting in speed regulation ability. We use numerical simulation with computational fluid dynamics (CFD) to investigate and analyze the speed of a simulated PIG with the valve unit adjusted by proportional-integral (PI) control under various in-pipe pressure conditions. Our simulation experiments are performed under different operating conditions in three pipe sizes (16″, 18″, and 22″ in diameter) to manifest the speed adaptation of the PIG with the modular valve unit add-on and PI control. Our results show that the PIG can effectively perform real-time adaptation (i.e., adjusting its valve angle) to maintain the desired speed. The valve design can be adjusted from 5 degrees (closed valve, resulting in high moving speed) to a maximum of 45 degrees (fully open valve, resulting in low moving speed). The speed of the PIG can be regulated from 0.59 m/s to 3.88 m/s in a 16″ pipe at 4.38 m/s (in-pipe fluid velocity), 2500 kPa (operating pressure), and 62 °C (operating temperature). Finally, the MC-PIG method is validated using a 3D-printed prototype in a 6″ pipe. Through the investigation, we observed that two factors influence speed adaptation; the pressure drop coefficient and friction of the PIG and pipeline. In conclusion, the results from the simulation and prototype show close characteristics with an acceptable error.","PeriodicalId":10967,"journal":{"name":"Day 1 Mon, November 15, 2021","volume":"21 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Day 1 Mon, November 15, 2021","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2118/207403-ms","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Passive and active hybrid pipeline inspection gauges (PIGs) have been used for in-pipe inspection. While a passive PIG cannot control its speed, the hybrid version can achieve this by using an integrated valve specifically designed and embedded in the PIG. This study proposes a generic new method for speed adaptation in PIGs (called MC-PIG) by introducing a generic, modular, controllable, external valve unit add-on for attaching to existing conventional (passive) PIGs with minimal change. The MC-PIG method is based on the principle of morphological computation with closed-loop control. It is achieved by regulating/computing the PIG's morphology (i.e., a modular rotary valve unit add-on) to control bypass flow. Adjustment of the valve angle can affect the flow rate passing through the PIG, resulting in speed regulation ability. We use numerical simulation with computational fluid dynamics (CFD) to investigate and analyze the speed of a simulated PIG with the valve unit adjusted by proportional-integral (PI) control under various in-pipe pressure conditions. Our simulation experiments are performed under different operating conditions in three pipe sizes (16″, 18″, and 22″ in diameter) to manifest the speed adaptation of the PIG with the modular valve unit add-on and PI control. Our results show that the PIG can effectively perform real-time adaptation (i.e., adjusting its valve angle) to maintain the desired speed. The valve design can be adjusted from 5 degrees (closed valve, resulting in high moving speed) to a maximum of 45 degrees (fully open valve, resulting in low moving speed). The speed of the PIG can be regulated from 0.59 m/s to 3.88 m/s in a 16″ pipe at 4.38 m/s (in-pipe fluid velocity), 2500 kPa (operating pressure), and 62 °C (operating temperature). Finally, the MC-PIG method is validated using a 3D-printed prototype in a 6″ pipe. Through the investigation, we observed that two factors influence speed adaptation; the pressure drop coefficient and friction of the PIG and pipeline. In conclusion, the results from the simulation and prototype show close characteristics with an acceptable error.