{"title":"Investigation of single-switch short-circuit fault characteristics of a PM machine drive with a current source inverter","authors":"Yichao Zhang, Wanjun Zhang, T. Jahns","doi":"10.1109/IEMDC.2015.7409178","DOIUrl":null,"url":null,"abstract":"This paper investigates the single-switch short-circuit fault response of a permanent magnet (PM) machine drive using a current source inverter (CSI). The CSI offers some appealing advantages over conventional voltage-source inverters (VSIs) during short-circuit fault conditions originating inside the inverter. Two post-fault strategies are investigated in this paper, consisting of either: 1) turning off all of the switches; or 2) turning on all of the switches in a controlled manner. Key features associated with the machine response to both of these post-fault strategies are presented and compared, leading to the conclusion that both make it possible to protect the machine. A combination of analysis, simulation, and experimental tests has been adopted for carrying out this investigation.","PeriodicalId":6477,"journal":{"name":"2015 IEEE International Electric Machines & Drives Conference (IEMDC)","volume":"177 1","pages":"967-973"},"PeriodicalIF":0.0000,"publicationDate":"2015-05-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE International Electric Machines & Drives Conference (IEMDC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMDC.2015.7409178","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8
Abstract
This paper investigates the single-switch short-circuit fault response of a permanent magnet (PM) machine drive using a current source inverter (CSI). The CSI offers some appealing advantages over conventional voltage-source inverters (VSIs) during short-circuit fault conditions originating inside the inverter. Two post-fault strategies are investigated in this paper, consisting of either: 1) turning off all of the switches; or 2) turning on all of the switches in a controlled manner. Key features associated with the machine response to both of these post-fault strategies are presented and compared, leading to the conclusion that both make it possible to protect the machine. A combination of analysis, simulation, and experimental tests has been adopted for carrying out this investigation.