Effects of Mn and Cu on descaling of hot-rolled 304L stainless steel in HCl and H2O2 mixtures

IF 2.4 4区 材料科学 Q2 MATERIALS SCIENCE, CHARACTERIZATION & TESTING
A. Lothongkum, Boonyapa Benjamalai, Nichit Hongbin, Nipa Prawetpai, Chockanan Tiyawatwitthaya, P. Wanichpongpan, G. Lothongkum
{"title":"Effects of Mn and Cu on descaling of hot-rolled 304L stainless steel in HCl and H2O2 mixtures","authors":"A. Lothongkum, Boonyapa Benjamalai, Nichit Hongbin, Nipa Prawetpai, Chockanan Tiyawatwitthaya, P. Wanichpongpan, G. Lothongkum","doi":"10.1515/mt-2023-0072","DOIUrl":null,"url":null,"abstract":"Abstract Descaling of stainless-steel black coil is an important step to produce white coil with smooth glossy surface. The AISI 304L black and white coils from a company containing 1.08–1.71Mn and 0.22–0.40Cu (wt%) were used to study the effects of Mn and Cu on descaling rate by potentiodynamic polarization technique at 25 °C. The pickling solutions were 0.5 M HCl and 0.5 M HCl mixed with H2O2 of 0.5, 0.88 and 1.76 M. The polarization curves of black and white coil samples measured in HCl–H2O2 mixture showed no passive range. The descaling rate of black coil oxide scales, and the corrosion potential (Ecorr) increased with H2O2 concentration. Low-Mn sample, that is 1.08%Mn0.23%Cu sample, showed higher descaling rate than high-Mn samples. No effects of Cu content on the descaling rate were observed. For white coil samples, the descaling rates were almost constant, but pitting on surface was observed. Passive films were eliminated. The corrosion potentials of black and white coil samples increased when adding H2O2 in HCl solution indicating an increase in cathodic reaction due to increase in dissolved oxygen. The corrosion potentials of 1.08%Mn0.23%Cu black and white coil samples were lower than those of high-Mn samples corresponding to less Mn oxide.","PeriodicalId":18231,"journal":{"name":"Materials Testing","volume":"65 1","pages":"1167 - 1178"},"PeriodicalIF":2.4000,"publicationDate":"2023-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Materials Testing","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1515/mt-2023-0072","RegionNum":4,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, CHARACTERIZATION & TESTING","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Descaling of stainless-steel black coil is an important step to produce white coil with smooth glossy surface. The AISI 304L black and white coils from a company containing 1.08–1.71Mn and 0.22–0.40Cu (wt%) were used to study the effects of Mn and Cu on descaling rate by potentiodynamic polarization technique at 25 °C. The pickling solutions were 0.5 M HCl and 0.5 M HCl mixed with H2O2 of 0.5, 0.88 and 1.76 M. The polarization curves of black and white coil samples measured in HCl–H2O2 mixture showed no passive range. The descaling rate of black coil oxide scales, and the corrosion potential (Ecorr) increased with H2O2 concentration. Low-Mn sample, that is 1.08%Mn0.23%Cu sample, showed higher descaling rate than high-Mn samples. No effects of Cu content on the descaling rate were observed. For white coil samples, the descaling rates were almost constant, but pitting on surface was observed. Passive films were eliminated. The corrosion potentials of black and white coil samples increased when adding H2O2 in HCl solution indicating an increase in cathodic reaction due to increase in dissolved oxygen. The corrosion potentials of 1.08%Mn0.23%Cu black and white coil samples were lower than those of high-Mn samples corresponding to less Mn oxide.
Mn和Cu对HCl和H2O2混合物中热轧304L不锈钢除鳞的影响
摘要:不锈钢黑卷除鳞是生产表面光滑的白卷的重要步骤。采用某公司生产的含锰1.08 ~ 1.71、铜0.22 ~ 0.40 (wt%)的AISI 304L黑白线圈,在25 °C条件下,采用动电位极化技术研究了锰和铜对除鳞率的影响。酸洗溶液分别为0.5 M HCl和0.5 M HCl与0.5、0.88和1.76 M的H2O2混合。在HCl - H2O2混合物中测量的黑色和白色线圈样品的极化曲线没有钝化范围。随着H2O2浓度的增加,黑卷氧化皮的除鳞率和腐蚀电位(Ecorr)均增大。低锰(1.08%Mn0.23%Cu)样品的除垢率高于高锰样品。未观察到铜含量对除垢率的影响。对于白色线圈样品,除鳞率基本不变,但表面有点蚀现象。被动式薄膜被淘汰。当HCl溶液中加入H2O2时,黑色和白色线圈样品的腐蚀电位升高,说明溶解氧增加导致阴极反应增强。1.08%Mn0.23%Cu黑色和白色线圈样品的腐蚀电位低于氧化锰较少的高Mn样品。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Materials Testing
Materials Testing 工程技术-材料科学:表征与测试
CiteScore
4.20
自引率
36.00%
发文量
165
审稿时长
4-8 weeks
期刊介绍: Materials Testing is a SCI-listed English language journal dealing with all aspects of material and component testing with a special focus on transfer between laboratory research into industrial application. The journal provides first-hand information on non-destructive, destructive, optical, physical and chemical test procedures. It contains exclusive articles which are peer-reviewed applying respectively high international quality criterions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信