Hardware-software complex for studying of breathing volume parameters

Q4 Medicine
I. I. Revinskaya, P. V. Kamlach, Yu. I. Liashchevich
{"title":"Hardware-software complex for studying of breathing volume parameters","authors":"I. I. Revinskaya, P. V. Kamlach, Yu. I. Liashchevich","doi":"10.29235/1561-8358-2023-68-2-149-155","DOIUrl":null,"url":null,"abstract":"In this paper, a developed hardware-software complex for studying volume parameters of breathing is considered. To estimate the volumetric parameters of breathing, a method for registering the movement of the chest and abdominal walls by changing the overall dimensions of the chest and abdomen with ranking according to the anatomical features of a person is proposed. A technique for researching the volumetric parameters of breathing based on the method of video recording of the movements of the chest and abdominal wall of a person was developed. The proposed method was used to estimate volume parameters of breathing among men aged 20–22 years. BMI (body mass index) ranged from 18.2 to 30.1 kg/m². The research of volumetric parameters of respiration was carried out using the hardware-software complex and the proposed technique for registering the biomechanics of breathing. Conclusions about the relation between volumetric parameters of breathing and the values of changes in the overall dimensions of the chest and abdomen during respiration were drawn. A correlation-regression analysis of the volumes of inhaled/exhaled air and the values of deviations of the overall dimensions of the chest and abdomen was carried out. The results obtained indicate a strong relation between volumetric parameters of breathing and the values of deviations in the overall dimensions of the chest and abdomen.","PeriodicalId":20584,"journal":{"name":"Proceedings of the National Academy of Sciences of Belarus, Medical series","volume":"8 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-07-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the National Academy of Sciences of Belarus, Medical series","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29235/1561-8358-2023-68-2-149-155","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

In this paper, a developed hardware-software complex for studying volume parameters of breathing is considered. To estimate the volumetric parameters of breathing, a method for registering the movement of the chest and abdominal walls by changing the overall dimensions of the chest and abdomen with ranking according to the anatomical features of a person is proposed. A technique for researching the volumetric parameters of breathing based on the method of video recording of the movements of the chest and abdominal wall of a person was developed. The proposed method was used to estimate volume parameters of breathing among men aged 20–22 years. BMI (body mass index) ranged from 18.2 to 30.1 kg/m². The research of volumetric parameters of respiration was carried out using the hardware-software complex and the proposed technique for registering the biomechanics of breathing. Conclusions about the relation between volumetric parameters of breathing and the values of changes in the overall dimensions of the chest and abdomen during respiration were drawn. A correlation-regression analysis of the volumes of inhaled/exhaled air and the values of deviations of the overall dimensions of the chest and abdomen was carried out. The results obtained indicate a strong relation between volumetric parameters of breathing and the values of deviations in the overall dimensions of the chest and abdomen.
研究呼吸量参数的软硬件复合体
本文考虑开发一种用于研究呼吸容积参数的软硬件系统。为了估计呼吸的体积参数,提出了一种根据人体解剖特征,通过改变胸腹总尺寸并排序来记录胸腹壁运动的方法。提出了一种基于视频记录人胸腹壁运动的呼吸容积参数研究方法。提出的方法用于估计20-22岁男性的呼吸容量参数。身体质量指数(BMI)从18.2到30.1 kg/m²不等。利用硬件-软件复合体和所提出的呼吸生物力学记录技术对呼吸容量参数进行了研究。得出呼吸容积参数与呼吸过程中胸腹总尺寸变化值之间的关系。对吸入/呼出气量与胸腹总体尺寸偏差值进行相关回归分析。所获得的结果表明,呼吸的体积参数与胸腹总体尺寸偏差值之间存在很强的关系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.40
自引率
0.00%
发文量
35
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信