An Echocardiographic Comparison of Sutureless and Conventional Aortic Valve Replacement: a Matched Case-Control Study

Aaron R Casha, A. Manché, L. Camilleri, K. Yamagata, S. Santucci, M. Gauci, J. Galea
{"title":"An Echocardiographic Comparison of Sutureless and Conventional Aortic Valve Replacement: a Matched Case-Control Study","authors":"Aaron R Casha, A. Manché, L. Camilleri, K. Yamagata, S. Santucci, M. Gauci, J. Galea","doi":"10.17987/ICFJ.V14I0.536","DOIUrl":null,"url":null,"abstract":"Background Patients at a high operative risk for conventional aortic valve replacement (AVR) may be offered sutureless valve implantation. Sutureless valves resemble conventional valves but incorporate an anchoring mechanism without using annular sutures. Methods Pre-operative and six month post-operative echocardiography data from our first year, single centre experience of sutureless valves was compared to conventional aortic valve replacements in patients matched for operative risk. Left ventricular ejection fraction, mean and peak AV gradients and inter-ventricular septal thickness, effective orifice area (EOA) and indexed effective orifice area (iEOA) were measured.  Results The drops in mean and peak pre- to post-operative gradients were greater in the sutureless group, p=0.039 and p=0.001 respectively. Post-operative EOA was 1.69 cm2 and 1.26 cm2 (p=0.001) in the sutureless and conventional groups. Similarly iEOA was 0.93 cm2 and 0.74 cm2 (p=0.001) in the sutureless and conventional groups. There was also a reduction in patient prosthesis mismatch (PPM) in the sutureless group as compared to the conventional group (Chi square test p=0.026). Post-operative inter-ventricular septal thickness was 1.13 cm2 in the sutureless group and 1.35 cm2 in the conventional group (p=0.011). Conclusions Use of sutureless valves with a stent framework resulted in larger EOA and iEOA and a diminution in PPM; and lead to a statistically significant faster regression in inter-ventricular septal thickness that is a measure of left ventricular mass. The rate and extent of regression in left ventricular hypertrophy after AVR is important since it determines long-term survival including mortality, heart failure and decreased admission rates.","PeriodicalId":32119,"journal":{"name":"International Cardiovascular Forum Journal","volume":"261 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-02-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Cardiovascular Forum Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17987/ICFJ.V14I0.536","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background Patients at a high operative risk for conventional aortic valve replacement (AVR) may be offered sutureless valve implantation. Sutureless valves resemble conventional valves but incorporate an anchoring mechanism without using annular sutures. Methods Pre-operative and six month post-operative echocardiography data from our first year, single centre experience of sutureless valves was compared to conventional aortic valve replacements in patients matched for operative risk. Left ventricular ejection fraction, mean and peak AV gradients and inter-ventricular septal thickness, effective orifice area (EOA) and indexed effective orifice area (iEOA) were measured.  Results The drops in mean and peak pre- to post-operative gradients were greater in the sutureless group, p=0.039 and p=0.001 respectively. Post-operative EOA was 1.69 cm2 and 1.26 cm2 (p=0.001) in the sutureless and conventional groups. Similarly iEOA was 0.93 cm2 and 0.74 cm2 (p=0.001) in the sutureless and conventional groups. There was also a reduction in patient prosthesis mismatch (PPM) in the sutureless group as compared to the conventional group (Chi square test p=0.026). Post-operative inter-ventricular septal thickness was 1.13 cm2 in the sutureless group and 1.35 cm2 in the conventional group (p=0.011). Conclusions Use of sutureless valves with a stent framework resulted in larger EOA and iEOA and a diminution in PPM; and lead to a statistically significant faster regression in inter-ventricular septal thickness that is a measure of left ventricular mass. The rate and extent of regression in left ventricular hypertrophy after AVR is important since it determines long-term survival including mortality, heart failure and decreased admission rates.
超声心动图比较无缝合与常规主动脉瓣置换术:匹配病例-对照研究
背景:传统主动脉瓣置换术(AVR)手术风险高的患者可以选择无缝线瓣膜植入术。无缝合线瓣膜类似于传统的瓣膜,但合并了锚定机制而不使用环形缝合线。方法对手术风险匹配的患者术前和术后6个月的超声心动图数据进行比较,对无缝合线瓣膜单中心经验进行比较。测量左室射血分数、平均和峰值AV梯度、室间隔厚度、有效孔口面积(EOA)和指数有效孔口面积(iEOA)。结果无缝线组平均梯度和峰值梯度下降幅度更大,p=0.039, p=0.001。未缝合组和常规组术后EOA分别为1.69 cm2和1.26 cm2 (p=0.001)。同样,未缝合组和常规组iEOA分别为0.93 cm2和0.74 cm2 (p=0.001)。与常规组相比,无缝线组患者假体失配(PPM)也有所减少(卡方检验p=0.026)。术后无缝线组室间隔厚度为1.13 cm2,常规组为1.35 cm2 (p=0.011)。结论在支架框架下使用无缝线瓣膜可导致更大的EOA和iEOA,降低PPM;并导致统计上显著的室间隔厚度更快的回归这是左心室质量的测量。AVR后左心室肥厚消退的速度和程度很重要,因为它决定了长期生存,包括死亡率、心力衰竭和入院率降低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
14 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书