Evaluation of the HemoCue HbA1c 501 System in Primary Care Settings

Anita Andersson, J. Lindh, Annika Eriksson
{"title":"Evaluation of the HemoCue HbA1c 501 System in Primary Care Settings","authors":"Anita Andersson, J. Lindh, Annika Eriksson","doi":"10.1097/POC.0000000000000140","DOIUrl":null,"url":null,"abstract":"Abstract The routine measurement of hemoglobin A1c (HbA1c) is recommended by major clinical diabetes organizations. By providing results rapidly with point-of-care devices, more timely decisions regarding optimal treatment can be made, and studies have confirmed that immediate feedback of HbA1c results improves glycemic control in patients with type 1 and insulin-treated type 2 diabetes mellitus. The aim of this study was to evaluate the performance of the HemoCue HbA1c 501 during regular use in primary care settings. The results verify that the HemoCue HbA1c 501 system is accurate and easy to use in the hands of the intended user in a primary care setting. This is based on the fact that more than 96% of results fall within 6% bias and a total coefficient of variation of less than 2%, thereby fulfilling the latest National Glycohemoglobin Standardization Program requirements.","PeriodicalId":20262,"journal":{"name":"Point of Care: The Journal of Near-Patient Testing & Technology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Point of Care: The Journal of Near-Patient Testing & Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/POC.0000000000000140","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

Abstract The routine measurement of hemoglobin A1c (HbA1c) is recommended by major clinical diabetes organizations. By providing results rapidly with point-of-care devices, more timely decisions regarding optimal treatment can be made, and studies have confirmed that immediate feedback of HbA1c results improves glycemic control in patients with type 1 and insulin-treated type 2 diabetes mellitus. The aim of this study was to evaluate the performance of the HemoCue HbA1c 501 during regular use in primary care settings. The results verify that the HemoCue HbA1c 501 system is accurate and easy to use in the hands of the intended user in a primary care setting. This is based on the fact that more than 96% of results fall within 6% bias and a total coefficient of variation of less than 2%, thereby fulfilling the latest National Glycohemoglobin Standardization Program requirements.
HemoCue HbA1c 501系统在初级保健机构中的评价
摘要:糖化血红蛋白(HbA1c)是临床主要糖尿病组织推荐的常规检测方法。通过即时护理设备快速提供结果,可以更及时地做出最佳治疗决策,研究证实,即时反馈HbA1c结果可改善1型和胰岛素治疗的2型糖尿病患者的血糖控制。本研究的目的是评估HemoCue HbA1c 501在初级保健机构常规使用期间的表现。结果验证了HemoCue HbA1c 501系统在初级保健环境中是准确且易于使用的。这是基于96%以上的结果偏差在6%以内,总变异系数小于2%,从而满足最新的国家糖蛋白标准化计划的要求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信