Multiresidue matrix solid phase dispersion (MSPD) extraction and gas chromatographic screening of nine chlorinated pesticides in catfish (Ictalurus punctatus) muscle tissue.
Austin R. Long, Michael D Crouch, Steven A. Barker
{"title":"Multiresidue matrix solid phase dispersion (MSPD) extraction and gas chromatographic screening of nine chlorinated pesticides in catfish (Ictalurus punctatus) muscle tissue.","authors":"Austin R. Long, Michael D Crouch, Steven A. Barker","doi":"10.1093/JAOAC/74.4.667","DOIUrl":null,"url":null,"abstract":"A multiresidue technique for extraction and gas chromatographic screening of 9 insecticide (lindane, heptachlor, aldrin, heptachlor epoxide, p,p'-DDE, dieldrin, endrin, p,p'-TDE, and p,p'-DDT) residues in catfish (Ictalurus punctatus) muscle tissue is presented. The 9 insecticides, plus dibutyl chlorendate internal standard, were fortified into catfish muscle tissue (0.5 g) and blended with 2 g C18 (octadecylsilyl derivatized silica reverse-phase material). The C18/muscle tissue matrix blend was fashioned into a column by adding the blend to a 10 mL syringe barrel containing 2 g activated Florisil. The insecticides were then eluted from the column with acetonitrile (8 mL), and a portion (2 microL) of the acetonitrile eluate was then directly analyzed by gas chromatography with electron capture detection. Unfortified blank controls were treated similarly. The resultant extracts contained pesticide analytes (31.25-500 ng/g) free of interfering compounds when analyzed. Correlation coefficients for the 9 extracted pesticide standard curves (linear regression analysis, n = 5) ranged from 0.9967 (+/- 0.0018) to 0.9999 (+/- 0.0001). Average percentage recoveries (82 +/- 4.8% to 97 +/- 3.6%, n = 25 for each insecticide), interassay (5.0 +/- 2.7% to 16.9 +/- 6.5%, n = 25 for each insecticide) and intraassay (1.8 to 4.7%, n = 5 for each insecticide) variabilities were indicative of an acceptable methodology for the analysis and screening of these residues in catfish muscle tissue.","PeriodicalId":14752,"journal":{"name":"Journal - Association of Official Analytical Chemists","volume":"118 1","pages":"667-70"},"PeriodicalIF":0.0000,"publicationDate":"1991-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"26","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal - Association of Official Analytical Chemists","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/JAOAC/74.4.667","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 26
Abstract
A multiresidue technique for extraction and gas chromatographic screening of 9 insecticide (lindane, heptachlor, aldrin, heptachlor epoxide, p,p'-DDE, dieldrin, endrin, p,p'-TDE, and p,p'-DDT) residues in catfish (Ictalurus punctatus) muscle tissue is presented. The 9 insecticides, plus dibutyl chlorendate internal standard, were fortified into catfish muscle tissue (0.5 g) and blended with 2 g C18 (octadecylsilyl derivatized silica reverse-phase material). The C18/muscle tissue matrix blend was fashioned into a column by adding the blend to a 10 mL syringe barrel containing 2 g activated Florisil. The insecticides were then eluted from the column with acetonitrile (8 mL), and a portion (2 microL) of the acetonitrile eluate was then directly analyzed by gas chromatography with electron capture detection. Unfortified blank controls were treated similarly. The resultant extracts contained pesticide analytes (31.25-500 ng/g) free of interfering compounds when analyzed. Correlation coefficients for the 9 extracted pesticide standard curves (linear regression analysis, n = 5) ranged from 0.9967 (+/- 0.0018) to 0.9999 (+/- 0.0001). Average percentage recoveries (82 +/- 4.8% to 97 +/- 3.6%, n = 25 for each insecticide), interassay (5.0 +/- 2.7% to 16.9 +/- 6.5%, n = 25 for each insecticide) and intraassay (1.8 to 4.7%, n = 5 for each insecticide) variabilities were indicative of an acceptable methodology for the analysis and screening of these residues in catfish muscle tissue.