Dynamic Behavior of Space Charge in Double-layer Insulation Structure under High External Electric Field

Ling Zhang, Yuxuan Xu, Quzong Gesang, Zhichao Qiao, Bo Zhang, Yuanxiang Zhou
{"title":"Dynamic Behavior of Space Charge in Double-layer Insulation Structure under High External Electric Field","authors":"Ling Zhang, Yuxuan Xu, Quzong Gesang, Zhichao Qiao, Bo Zhang, Yuanxiang Zhou","doi":"10.1109/ICEMPE51623.2021.9509147","DOIUrl":null,"url":null,"abstract":"Compared with single-layer insulation, multilayer insulation structures have more forms and features, thus are widely used in the fields of oil-paper insulation, power cables and communication cables. However, there are fewer researches conducted on the space charge characteristics of multi-layer insulation structures, and the analysis of the interface space charge in those structures is not in-depth. This article takes the ‘skin-foam-skin’ insulation structure of the frequency-shift pulse track signal cables as an example, which are commonly used in railway systems. We carried out room-temperature space charge measurement of the three parts of the ‘skin-foam-skin’ insulation including LDPE, FPE, HDPE, and the double-layer structure of FPE/HDPE and FPE/LDPE separately, based on pulse electro-acoustic (PEA) method. Meanwhile, thermal property of PE samples was also tested. The result shows that a large amount of positive charge injection and accumulation occurred in the single-layer HDPE films. And due to the difference in the carrier mobility during the depolarization process, there was obvious positive charge accumulation near the interface of the FPE/LDPE double-layer structure. Besides, a small amount of negative charge is accumulated at the interface of the FPE/HDPE double-layer structure. This result not only provides a reference for the characterization and evaluation of the space charge characteristics of multi-layer insulation materials, but also provides basic data support for the subsequent selection and extraction of aging characteristics of multi-layer insulation.","PeriodicalId":7083,"journal":{"name":"2021 International Conference on Electrical Materials and Power Equipment (ICEMPE)","volume":"24 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2021-04-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 International Conference on Electrical Materials and Power Equipment (ICEMPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEMPE51623.2021.9509147","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Compared with single-layer insulation, multilayer insulation structures have more forms and features, thus are widely used in the fields of oil-paper insulation, power cables and communication cables. However, there are fewer researches conducted on the space charge characteristics of multi-layer insulation structures, and the analysis of the interface space charge in those structures is not in-depth. This article takes the ‘skin-foam-skin’ insulation structure of the frequency-shift pulse track signal cables as an example, which are commonly used in railway systems. We carried out room-temperature space charge measurement of the three parts of the ‘skin-foam-skin’ insulation including LDPE, FPE, HDPE, and the double-layer structure of FPE/HDPE and FPE/LDPE separately, based on pulse electro-acoustic (PEA) method. Meanwhile, thermal property of PE samples was also tested. The result shows that a large amount of positive charge injection and accumulation occurred in the single-layer HDPE films. And due to the difference in the carrier mobility during the depolarization process, there was obvious positive charge accumulation near the interface of the FPE/LDPE double-layer structure. Besides, a small amount of negative charge is accumulated at the interface of the FPE/HDPE double-layer structure. This result not only provides a reference for the characterization and evaluation of the space charge characteristics of multi-layer insulation materials, but also provides basic data support for the subsequent selection and extraction of aging characteristics of multi-layer insulation.
高外加电场作用下双层绝缘结构中空间电荷的动态行为
多层绝缘结构与单层绝缘相比,具有更多的形式和特点,广泛应用于油纸绝缘、电力电缆、通信电缆等领域。然而,对多层绝缘结构空间电荷特性的研究较少,对多层绝缘结构中界面空间电荷的分析也不深入。本文以铁路系统中常用的移频脉冲轨道信号电缆的“表皮-泡沫-表皮”绝缘结构为例。基于脉冲电声(PEA)方法,分别对LDPE、FPE、HDPE、FPE/HDPE和FPE/LDPE双层结构的“皮肤-泡沫-皮肤”绝缘层进行了室温空间电荷测量。同时对PE样品的热性能进行了测试。结果表明,单层HDPE薄膜中存在大量的正电荷注入和积累。由于去极化过程中载流子迁移率的差异,FPE/LDPE双层结构界面附近存在明显的正电荷积累。此外,FPE/HDPE双层结构的界面处有少量的负电荷积累。该结果不仅为多层绝缘材料空间电荷特性的表征和评价提供了参考,也为后续多层绝缘老化特性的选择和提取提供了基础数据支持。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信