{"title":"Digital Holography for Local Heat Flux Measurement along the Surface of Heated Wire","authors":"Varun Kumar, C. Shakher","doi":"10.1364/CLEO_AT.2019.JW2A.1","DOIUrl":null,"url":null,"abstract":"In this paper, local heat flux Q(y) and convective heat transfer coefficient (hc) is measured along the surface of electrically heated wire using digital holographic interferometry (DHI). Experiments were performed on tungsten wire of different diameters.","PeriodicalId":72688,"journal":{"name":"Conference on Lasers and Electro-optics : (CLEO). Conference on Lasers and Electro-optics","volume":"16 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-05-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference on Lasers and Electro-optics : (CLEO). Conference on Lasers and Electro-optics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1364/CLEO_AT.2019.JW2A.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
In this paper, local heat flux Q(y) and convective heat transfer coefficient (hc) is measured along the surface of electrically heated wire using digital holographic interferometry (DHI). Experiments were performed on tungsten wire of different diameters.