Effect of Gamma Rays on The Bulk Etching Rate of LR-115 Detector

H. Yousef
{"title":"Effect of Gamma Rays on The Bulk Etching Rate of LR-115 Detector","authors":"H. Yousef","doi":"10.9790/4861-0902011416","DOIUrl":null,"url":null,"abstract":"It is important to measure the bulk-etching rate for any solid state nuclear track detectors, because they have an application in different fields of sciences. The effect of gamma rays emitted from 60 Co source with different doses on LR-115 detector was studied. The bulk etching rate of the detectors was measured before and after irradiation using gamma source. From the results the values of the bulk etching rate of LR-115 without gamma rays have been 3.10 μmh −1 and that under gamma irradiation with different doses were ranged from 4.60 to 8.77 μmh −1 . This means that the values of the bulk etch rate increase with increasing gamma doses.","PeriodicalId":14502,"journal":{"name":"IOSR Journal of Applied Physics","volume":"129 1","pages":"14-16"},"PeriodicalIF":0.0000,"publicationDate":"2017-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IOSR Journal of Applied Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.9790/4861-0902011416","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

It is important to measure the bulk-etching rate for any solid state nuclear track detectors, because they have an application in different fields of sciences. The effect of gamma rays emitted from 60 Co source with different doses on LR-115 detector was studied. The bulk etching rate of the detectors was measured before and after irradiation using gamma source. From the results the values of the bulk etching rate of LR-115 without gamma rays have been 3.10 μmh −1 and that under gamma irradiation with different doses were ranged from 4.60 to 8.77 μmh −1 . This means that the values of the bulk etch rate increase with increasing gamma doses.
伽马射线对LR-115探测器体腐蚀速率的影响
对于任何固体核径迹探测器来说,测量体积腐蚀速率都是非常重要的,因为它们在不同的科学领域都有应用。研究了不同剂量60钴源发射的伽马射线对LR-115探测器的影响。测量了辐照前后探测器的体腐蚀速率。结果表明,在没有γ射线照射时,LR-115的体刻蚀速率为3.10 μmh−1,在不同剂量的γ射线照射下,LR-115的体刻蚀速率为4.60 ~ 8.77 μmh−1。这意味着随着伽马剂量的增加,体腐蚀速率的值增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信