Application of high-sensitivity carbon isotope techniques— a question of blanks

P.D. Yates, I.P. Wright, C.T. Pillinger
{"title":"Application of high-sensitivity carbon isotope techniques— a question of blanks","authors":"P.D. Yates,&nbsp;I.P. Wright,&nbsp;C.T. Pillinger","doi":"10.1016/0009-2541(92)90205-J","DOIUrl":null,"url":null,"abstract":"<div><p>The performance of a new carbon stable isotope static mass spectrometer over the sample size range 10 pmol to 1 nmol is reviewed with reference to standard data gathered over a year of operation. Specimens of known isotopic composition and zero enrichment tests suggest that the instrument is accurate to within±0.5‰ over the entire sample size range, with precision only becoming worse than∼±;1‰at&lt; 80pmol. Efforts to obtain “blanks” compatible with the above performance are also reviewed. A procedure is available which controls the total blank in a stepped combustion, from room temperature to 1200°C, to 1 nmol; in the temperature range of most inserest for extraterrestrial samples (600–1200°C),⩽50pmol can be achieved. However, a real benefit of the new instrument is that isotopic compositions of the blanks can be accurately obtained, so allowing a proper assessment of its causes and a correction of sample data if desired.</p></div>","PeriodicalId":100231,"journal":{"name":"Chemical Geology: Isotope Geoscience section","volume":"101 1","pages":"Pages 81-91"},"PeriodicalIF":0.0000,"publicationDate":"1992-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0009-2541(92)90205-J","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chemical Geology: Isotope Geoscience section","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/000925419290205J","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

Abstract

The performance of a new carbon stable isotope static mass spectrometer over the sample size range 10 pmol to 1 nmol is reviewed with reference to standard data gathered over a year of operation. Specimens of known isotopic composition and zero enrichment tests suggest that the instrument is accurate to within±0.5‰ over the entire sample size range, with precision only becoming worse than∼±;1‰at< 80pmol. Efforts to obtain “blanks” compatible with the above performance are also reviewed. A procedure is available which controls the total blank in a stepped combustion, from room temperature to 1200°C, to 1 nmol; in the temperature range of most inserest for extraterrestrial samples (600–1200°C),⩽50pmol can be achieved. However, a real benefit of the new instrument is that isotopic compositions of the blanks can be accurately obtained, so allowing a proper assessment of its causes and a correction of sample data if desired.

高灵敏度碳同位素技术的应用——一个空白问题
在10 pmol到1 nmol的样品尺寸范围内,对一种新型碳稳定同位素静态质谱仪的性能进行了评价,并参考了一年以上运行中收集的标准数据。已知同位素组成的标本和零富集试验表明,该仪器在整个样本量范围内的精度在±0.5‰以内,精度仅低于±1‰。80 pmol。还审查了获得与上述性能兼容的“空白”的努力。有一种程序可以控制分步燃烧的总空白量,从室温到1200℃,到1nmol;在最适合地外样品的温度范围(600-1200℃),可达到≥50pmol。然而,新仪器的一个真正好处是可以准确地获得空白的同位素组成,因此可以对其原因进行适当的评估,并在需要时对样品数据进行校正。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信