{"title":"Improvement of sensory odour intensity scale using 1-butanol reference solutions for environmental odour evaluation","authors":"","doi":"10.30955/gnj.002779","DOIUrl":null,"url":null,"abstract":"For appropriate evaluation of environmental odours, it is necessary to develop a reliable odour measurement scale. Odour intensity reflects people’s perception of odours and contributes to effective odour management. In this study, Japanese conventional six-point odour intensity scale was reconsidered to ensure equal intervals between odour intensity levels. A new series of six dilution steps of 1-butanol solutions with a concentration of 0, 10, 600, 2600, 9000 and 22500 ppm (vol/vol) was proposed and explanatory labels for odour intensity levels were determined. In addition, polyethylene (PE) bottles were proposed as containers for 1-butanol odour intensity reference solutions for convenience in on-site handling, and the effectiveness of PE bottles was suggested. These results showed that the new odour intensity scale would be applicable to on-site investigations and practically useful for all people related to environmental odour evaluation. \n","PeriodicalId":23539,"journal":{"name":"Volume 1, Issue 3","volume":"36 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2018-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 1, Issue 3","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30955/gnj.002779","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
For appropriate evaluation of environmental odours, it is necessary to develop a reliable odour measurement scale. Odour intensity reflects people’s perception of odours and contributes to effective odour management. In this study, Japanese conventional six-point odour intensity scale was reconsidered to ensure equal intervals between odour intensity levels. A new series of six dilution steps of 1-butanol solutions with a concentration of 0, 10, 600, 2600, 9000 and 22500 ppm (vol/vol) was proposed and explanatory labels for odour intensity levels were determined. In addition, polyethylene (PE) bottles were proposed as containers for 1-butanol odour intensity reference solutions for convenience in on-site handling, and the effectiveness of PE bottles was suggested. These results showed that the new odour intensity scale would be applicable to on-site investigations and practically useful for all people related to environmental odour evaluation.