Regional Variations in Postlens Tear Layer Thickness During Scleral Lens Wear.

Stephen J. Vincent, D. Alonso-Caneiro, M. Collins
{"title":"Regional Variations in Postlens Tear Layer Thickness During Scleral Lens Wear.","authors":"Stephen J. Vincent, D. Alonso-Caneiro, M. Collins","doi":"10.1097/ICL.0000000000000676","DOIUrl":null,"url":null,"abstract":"OBJECTIVES\nTo quantify regional variations in the postlens tear layer (PLTL) thickness during scleral lens wear.\n\n\nMETHODS\nFifteen healthy adults (22±3 years) with normal corneae were fitted with a 16.5-mm-diameter rotationally symmetric scleral lens in one eye. The PLTL thickness was measured across the central 5 mm at 0, 15, 30, 45, 60, 90, 120, 240, and 480 min after lens insertion using a 12 radial line scan optical coherence tomography imaging protocol. Regional analyses were conducted by dividing the PLTL into 8 equal 45° segments.\n\n\nRESULTS\nA tilted optic zone was observed immediately after lens insertion with the greatest PLTL asymmetry between nasal and temporal regions (156±22 μm more clearance temporally) and superior nasal and inferotemporal regions (124±12 μm more clearance inferotemporally). The magnitude of lens settling observed in each region was associated with the initial PLTL (r=0.59-0.77, P≤0.02). The superior nasal PLTL furthest from the pupil center stabilized after 90 min compared with other regions which stabilized after 4 hr. On average, after 8 hr of lens wear, the PLTL decreased by 29% and PLTL asymmetries between opposing regions decreased by 30%.\n\n\nCONCLUSIONS\nThe PLTL was thickest temporally and thinnest nasally in healthy eyes fitted with rotationally symmetric scleral lenses, most likely because of regional differences in underlying scleral elevation, eyelid forces, and lens centration. Postlens tear layer asymmetries diminished with lens wear, and stabilization occurred more rapidly in regions with less corneal clearance immediately after lens insertion.","PeriodicalId":12216,"journal":{"name":"Eye & Contact Lens: Science & Clinical Practice","volume":"24 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-11-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye & Contact Lens: Science & Clinical Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/ICL.0000000000000676","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

Abstract

OBJECTIVES To quantify regional variations in the postlens tear layer (PLTL) thickness during scleral lens wear. METHODS Fifteen healthy adults (22±3 years) with normal corneae were fitted with a 16.5-mm-diameter rotationally symmetric scleral lens in one eye. The PLTL thickness was measured across the central 5 mm at 0, 15, 30, 45, 60, 90, 120, 240, and 480 min after lens insertion using a 12 radial line scan optical coherence tomography imaging protocol. Regional analyses were conducted by dividing the PLTL into 8 equal 45° segments. RESULTS A tilted optic zone was observed immediately after lens insertion with the greatest PLTL asymmetry between nasal and temporal regions (156±22 μm more clearance temporally) and superior nasal and inferotemporal regions (124±12 μm more clearance inferotemporally). The magnitude of lens settling observed in each region was associated with the initial PLTL (r=0.59-0.77, P≤0.02). The superior nasal PLTL furthest from the pupil center stabilized after 90 min compared with other regions which stabilized after 4 hr. On average, after 8 hr of lens wear, the PLTL decreased by 29% and PLTL asymmetries between opposing regions decreased by 30%. CONCLUSIONS The PLTL was thickest temporally and thinnest nasally in healthy eyes fitted with rotationally symmetric scleral lenses, most likely because of regional differences in underlying scleral elevation, eyelid forces, and lens centration. Postlens tear layer asymmetries diminished with lens wear, and stabilization occurred more rapidly in regions with less corneal clearance immediately after lens insertion.
巩膜晶状体磨损过程中晶状体后撕裂层厚度的区域差异。
目的量化巩膜晶状体磨损过程中晶状体后撕裂层(PLTL)厚度的区域变化。方法15例(22±3岁)正常角膜的健康成人单眼植入直径16.5 mm的旋转对称巩膜晶体。使用12径向线扫描光学相干层析成像方案,在透镜插入后0,15,30,45,60,90,120,240和480分钟测量中心5mm的PLTL厚度。通过将PLTL划分为8个相等的45°段进行区域分析。结果置入晶状体后即刻观察到斜视区,鼻颞区与上颞区PLTL不对称最大(颞间间隙增加156±22 μm),上鼻颞间间隙增加124±12 μm)。各区域晶状体沉降的大小与初始PLTL相关(r=0.59-0.77, P≤0.02)。离瞳孔中心最远的上鼻PLTL在90 min后稳定,其他区域在4小时后稳定。平均而言,镜片佩戴8小时后,PLTL下降了29%,相对区域之间的PLTL不对称性下降了30%。结论:健康眼配旋转对称巩膜晶状体时,睑板在时间上最厚,在鼻腔上最薄,这可能是由于区域间巩膜下高度、眼睑受力和晶状体集中的差异。晶状体后撕裂层不对称随着晶状体的磨损而减少,晶状体植入后角膜间隙较少的区域稳定发生得更快。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信