Preconcentration of Cd(II) by chemically converted graphene sheets adsorbed on surfactant- coated C18 before determination by flame atomic absorption spectrometry (FAAS)
{"title":"Preconcentration of Cd(II) by chemically converted graphene sheets adsorbed on surfactant- coated C18 before determination by flame atomic absorption spectrometry (FAAS)","authors":"A. Moghimi, M. Farahmandjou","doi":"10.5897/AJPAC2013.0542","DOIUrl":null,"url":null,"abstract":"A simple, highly sensitive, accurate and selective method for determination of trace amounts of Cd(II) in water samples is presented. A novel chemically converted graphene sheets (CCG) solid-phase extraction adsorbent was synthesized by CCG sheets. The stability of a CCG especially in concentrated hydrochloric acid was studied which used as a recycling and preconcentration reagent for further uses of CCG. The method is based on CCG of Cd(II) on surfactant-coated C18, modified with a CCG. The retained ions were then eluted with 4 ml of 4 M nitric acid and determined by flame atomic absorption spectrometry (FAAS) at 283.3 nm for Cd. The influence of flow rates of sample and eluent solutions, pH, breakthrough volume, effect of foreign ions on chelation and recovery were investigated. 1.5 g of surfactant-coated C18 adsorbs 40 mg of the Schiff’s base which in turn can retain 15.2 ± 0.8 mg of each of the two ions. The limit of detection (3σ) for Cd(II) was found to be 3.20 ng L-1. The enrichment factors for both ions are 100. The mentioned method was successfully applied on determination of Cd in different water samples. The ions were also speciated by means of three-column system. Key words: Determination of Cd, preconcentration, chemically converted graphene sheets (CCG), flame atomic absorption spectrometry (FAAS).","PeriodicalId":7556,"journal":{"name":"African Journal of Pure and Applied Chemistry","volume":"20 1","pages":"1-8"},"PeriodicalIF":0.0000,"publicationDate":"2014-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"African Journal of Pure and Applied Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5897/AJPAC2013.0542","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
A simple, highly sensitive, accurate and selective method for determination of trace amounts of Cd(II) in water samples is presented. A novel chemically converted graphene sheets (CCG) solid-phase extraction adsorbent was synthesized by CCG sheets. The stability of a CCG especially in concentrated hydrochloric acid was studied which used as a recycling and preconcentration reagent for further uses of CCG. The method is based on CCG of Cd(II) on surfactant-coated C18, modified with a CCG. The retained ions were then eluted with 4 ml of 4 M nitric acid and determined by flame atomic absorption spectrometry (FAAS) at 283.3 nm for Cd. The influence of flow rates of sample and eluent solutions, pH, breakthrough volume, effect of foreign ions on chelation and recovery were investigated. 1.5 g of surfactant-coated C18 adsorbs 40 mg of the Schiff’s base which in turn can retain 15.2 ± 0.8 mg of each of the two ions. The limit of detection (3σ) for Cd(II) was found to be 3.20 ng L-1. The enrichment factors for both ions are 100. The mentioned method was successfully applied on determination of Cd in different water samples. The ions were also speciated by means of three-column system. Key words: Determination of Cd, preconcentration, chemically converted graphene sheets (CCG), flame atomic absorption spectrometry (FAAS).
提出了一种简便、灵敏、准确、选择性高的测定水样中痕量Cd(II)的方法。以石墨烯片为原料合成了一种新型化学转化石墨烯片固相萃取吸附剂。研究了CCG在浓盐酸中的稳定性,并将其作为回收和预富集试剂,为CCG的进一步利用做准备。该方法是将Cd(II)涂覆在表面活性剂C18上,并用CCG进行修饰。用4 ml 4 M硝酸洗脱残留离子,用火焰原子吸收光谱法(FAAS)在283.3 nm处测定Cd。考察样品流速、洗脱液流速、pH、突破体积、外源离子对螯合和回收率的影响。1.5 g表面活性剂包覆的C18吸附40毫克的希夫碱,而希夫碱又能保留两种离子各15.2±0.8毫克。Cd(II)的检出限(3σ)为3.20 ng L-1。两种离子的富集因子均为100。该方法成功地应用于不同水样中镉的测定。用三柱体系对离子进行了表征。关键词:镉的测定,预富集,化学转化石墨烯片,火焰原子吸收光谱法