{"title":"Corona stabilization at negative impulse stress in SF/sub 6/ and SF/sub 6/-N/sub 2/-mixtures","authors":"W. Pfeiffer, H. Welke, V. Zimmer","doi":"10.1109/CEIDP.1989.69526","DOIUrl":null,"url":null,"abstract":"Measurements have been made to evaluate the characteristics of impulse corona at negative impulse stress. It is shown that for the parameters investigated the corona onset voltage is a linear function of the degree of homogeneity of the electrode arrangement for different pressures and mixture ratios. It is also shown that the corona onset voltage is a linear function of the pressure for different gap distances and mixture ratios for the parameters investigated. The breakdown voltage at impulse stress has been measured for a constant formative time lag, for different gap distances, for various degrees of homogeneity ( eta =E/sub mean//E/sub max/ was varied from 0.76 to 0.04), and for different SF/sub 6/-N/sub 2/ mixtures. Measurements of the breakdown voltage have shown that the corona stabilizing effect exists up to a mixture ratio of 10% SF/sub 6/ to N/sub 2/. It has been found that a slightly inhomogeneous electrode arrangement ( eta =0.26) has a lower dielectric strength than a strongly inhomogeneous electrode arrangement ( eta =0.04).<<ETX>>","PeriodicalId":10719,"journal":{"name":"Conference on Electrical Insulation and Dielectric Phenomena,","volume":"8 1","pages":"75-80"},"PeriodicalIF":0.0000,"publicationDate":"1989-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference on Electrical Insulation and Dielectric Phenomena,","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.1989.69526","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Measurements have been made to evaluate the characteristics of impulse corona at negative impulse stress. It is shown that for the parameters investigated the corona onset voltage is a linear function of the degree of homogeneity of the electrode arrangement for different pressures and mixture ratios. It is also shown that the corona onset voltage is a linear function of the pressure for different gap distances and mixture ratios for the parameters investigated. The breakdown voltage at impulse stress has been measured for a constant formative time lag, for different gap distances, for various degrees of homogeneity ( eta =E/sub mean//E/sub max/ was varied from 0.76 to 0.04), and for different SF/sub 6/-N/sub 2/ mixtures. Measurements of the breakdown voltage have shown that the corona stabilizing effect exists up to a mixture ratio of 10% SF/sub 6/ to N/sub 2/. It has been found that a slightly inhomogeneous electrode arrangement ( eta =0.26) has a lower dielectric strength than a strongly inhomogeneous electrode arrangement ( eta =0.04).<>
SF/sub - 6/和SF/sub - 6/-N/sub - 2/-混合物在负脉冲应力下的电晕稳定
对负脉冲应力下脉冲电晕的特性进行了测量。结果表明,对于所研究的参数,在不同压力和混合比下,电晕起始电压是电极排列均匀度的线性函数。研究还表明,在不同间隙距离和不同混合比例下,电晕起始电压是压力的线性函数。在一定的形成滞后、不同的间隙距离、不同程度的均匀性(eta =E/sub mean//E/sub max/从0.76变化到0.04)以及不同的SF/sub 6/-N/sub 2/混合物下,脉冲应力击穿电压被测量。击穿电压的测量表明,直到10%的SF/sub - 6/与N/sub - 2/混合时,电晕稳定效应仍然存在。我们发现,稍微不均匀的电极排列(eta =0.26)比强烈不均匀的电极排列(eta =0.04)具有更低的介电强度
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信