The Temperature Effect on U and Coil Shaped POF Sensors to Detect Refractive Index Change

IF 2.3 4区 物理与天体物理 Q2 OPTICS
T. Tabaru
{"title":"The Temperature Effect on U and Coil Shaped POF Sensors to Detect Refractive Index Change","authors":"T. Tabaru","doi":"10.1080/01468030.2021.1904059","DOIUrl":null,"url":null,"abstract":"ABSTRACT The effect of the temperature on refractive index (RI) sensors based on U and Coil-shaped plastic optical fiber (POF) was investigated. For this purpose, four POF-RI sensor probes were produced, and RI changes caused by ethanol changes in solutions were detected. Two of the produced probes were U-shaped, while the other two were Coil-shaped. For the first time in the literature, the effect of both the geometry of the U and Coil-shaped POF-RI sensors on the sensor parameters and the effect of the medium temperature have been analyzed together. As a result of the experiments conducted at 25°C, the best RI change detection sensitivity, linearity, and resolution values were determined as 821%/RIU, 0.9974 (R2), 5.18 × 10−4. In addition, temperature dependence loss (TDL) and temperature dependence RI deviation (TDR) were measured at different temperatures (25–40°C) in the 1.3346–1.45 RI range, and the effect of temperature change on POF-RI sensor probes was characterized.","PeriodicalId":50449,"journal":{"name":"Fiber and Integrated Optics","volume":"28 1","pages":"48 - 69"},"PeriodicalIF":2.3000,"publicationDate":"2021-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fiber and Integrated Optics","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1080/01468030.2021.1904059","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPTICS","Score":null,"Total":0}
引用次数: 4

Abstract

ABSTRACT The effect of the temperature on refractive index (RI) sensors based on U and Coil-shaped plastic optical fiber (POF) was investigated. For this purpose, four POF-RI sensor probes were produced, and RI changes caused by ethanol changes in solutions were detected. Two of the produced probes were U-shaped, while the other two were Coil-shaped. For the first time in the literature, the effect of both the geometry of the U and Coil-shaped POF-RI sensors on the sensor parameters and the effect of the medium temperature have been analyzed together. As a result of the experiments conducted at 25°C, the best RI change detection sensitivity, linearity, and resolution values were determined as 821%/RIU, 0.9974 (R2), 5.18 × 10−4. In addition, temperature dependence loss (TDL) and temperature dependence RI deviation (TDR) were measured at different temperatures (25–40°C) in the 1.3346–1.45 RI range, and the effect of temperature change on POF-RI sensor probes was characterized.
温度对U形和线圈形POF传感器折射率变化的影响
研究了温度对基于U形和卷形塑料光纤(POF)的折射率传感器的影响。为此,我们制作了四个POF-RI传感器探针,检测了溶液中乙醇变化引起的RI变化。生产的两个探针是u形的,而另外两个是线圈形的。在文献中首次分析了U型和线圈型POF-RI传感器的几何形状对传感器参数的影响以及介质温度的影响。结果表明,在25°C条件下,最佳的RI变化检测灵敏度、线性度和分辨率分别为821%/RIU、0.9974 (R2)、5.18 × 10−4。此外,在1.3346 ~ 1.45 RI范围内测量了不同温度(25 ~ 40℃)下的温度依赖损耗(TDL)和温度依赖RI偏差(TDR),表征了温度变化对POF-RI传感器探头的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.40
自引率
0.00%
发文量
4
审稿时长
>12 weeks
期刊介绍: Fiber and Integrated Optics , now incorporating the International Journal of Optoelectronics, is an international bimonthly journal that disseminates significant developments and in-depth surveys in the fields of fiber and integrated optics. The journal is unique in bridging the major disciplines relevant to optical fibers and electro-optical devices. This results in a balanced presentation of basic research, systems applications, and economics. For more than a decade, Fiber and Integrated Optics has been a valuable forum for scientists, engineers, manufacturers, and the business community to exchange and discuss techno-economic advances in the field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信