{"title":"Analysis and Design of Transmission Tower with Isolated Footing","authors":"","doi":"10.46243/jst.2020.v5.i5.pp35-42","DOIUrl":null,"url":null,"abstract":"A transmission tower is a tall structure, usually a steel lattice tower used to support an overhead\npower line. They are used in high voltage AC and DC systems. Steel tower structure resting on footings are\ncurrently becoming popular in any geographical location for electrical transmission, microwave transmission\netc. It is necessary to have an understudy of the behavior of such structures and provide an economical design.\nTo understand the performance of such high rise structures, it is necessary to know their behavior considering\nthe soil structure interaction. Modeling of Transmission tower for the validation purpose is done. The basic\nsoil properties of laterite were also found accordingly. Here the entire transmission tower with the isolated\nfooting is modeled and analyzed in STAAD Pro V8i and STAAD Foundation software. The total load\ntransmitted to each tower leg is found using STAAAD Pro and the size of isolated footing under each tower leg\nis determined using the STAAD Foundation software respectively. If required the soil structure interaction\neffects (SSI) can also be found easily","PeriodicalId":23534,"journal":{"name":"Volume 5, Issue 4","volume":"14 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 5, Issue 4","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.46243/jst.2020.v5.i5.pp35-42","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
A transmission tower is a tall structure, usually a steel lattice tower used to support an overhead
power line. They are used in high voltage AC and DC systems. Steel tower structure resting on footings are
currently becoming popular in any geographical location for electrical transmission, microwave transmission
etc. It is necessary to have an understudy of the behavior of such structures and provide an economical design.
To understand the performance of such high rise structures, it is necessary to know their behavior considering
the soil structure interaction. Modeling of Transmission tower for the validation purpose is done. The basic
soil properties of laterite were also found accordingly. Here the entire transmission tower with the isolated
footing is modeled and analyzed in STAAD Pro V8i and STAAD Foundation software. The total load
transmitted to each tower leg is found using STAAAD Pro and the size of isolated footing under each tower leg
is determined using the STAAD Foundation software respectively. If required the soil structure interaction