{"title":"Compensation of two important non-linearities in the globally linear mechanical behavior of the human lung","authors":"C. Renotte, M. Remy, P. Saucez, M. Mauroy","doi":"10.1109/IEMBS.1992.5761169","DOIUrl":null,"url":null,"abstract":"A mathematical model has been developed that describes the mechanical behavior of the human ventilatory system in healthy subjects under plethysmograph test conditions. We have shown that the introduction of the non-linear gas compression law into the mechanical model of the lung, while assuming air resistance to be a constant, leads to erroneous plethysmographic curves. When \"volume-resistance\" dependence is introduced, however, plethysmographic curves will then form the same shape as those usually recorded in healthy subjects. It is therefore evident that the semblance of linearity does not correspond with the more complex reality of the global behavior of the lung in which some non-linearities may offset each other.","PeriodicalId":6457,"journal":{"name":"1992 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":"39 1","pages":"681-683"},"PeriodicalIF":0.0000,"publicationDate":"1992-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1992 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMBS.1992.5761169","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

A mathematical model has been developed that describes the mechanical behavior of the human ventilatory system in healthy subjects under plethysmograph test conditions. We have shown that the introduction of the non-linear gas compression law into the mechanical model of the lung, while assuming air resistance to be a constant, leads to erroneous plethysmographic curves. When "volume-resistance" dependence is introduced, however, plethysmographic curves will then form the same shape as those usually recorded in healthy subjects. It is therefore evident that the semblance of linearity does not correspond with the more complex reality of the global behavior of the lung in which some non-linearities may offset each other.
人体肺部整体线性力学行为中两个重要非线性的补偿
已经开发了一个数学模型来描述健康受试者在容积脉搏波测试条件下人体通气系统的机械行为。我们已经证明,在假定空气阻力为常数的情况下,将非线性气体压缩定律引入肺的力学模型会导致错误的容积脉搏曲线。然而,当引入“容量-阻力”依赖性时,体积脉搏曲线将形成与通常在健康受试者中记录的曲线相同的形状。因此,很明显,线性的表面并不符合肺的整体行为的更复杂的现实,其中一些非线性可能相互抵消。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信