{"title":"Use and repeatability of 3D light scanning to measure transverse dorsal profile size and symmetry in the thoracic region in horses","authors":"G. Tabor, D. Marlin, J.M. Williams","doi":"10.3920/cep220016","DOIUrl":null,"url":null,"abstract":"Equine epaxial muscle size, thoracolumbar profile and symmetry in horses is of clinical interest due to relationships with pain and pathology. Flexible-curve rulers have previously been used to gather reliable, objective measures of thoracic profile, however, 3D light-scanning offers a potential non-contact alternative method to estimate cross sectional area (CSA) of the region. 3D light-scans of the thoracic epaxial region were taken from ten endurance horses (7 geldings, 3 mares; 8±2 years). Total CSA of the combined epaxial musculature, using computer software, was calculated at scapula and T18 levels (depth: 15 cm). Intra and inter-rater (n=3) reliability of CSA measurements was assessed using Friedman’s analyses and post-hoc Wilcoxon rank tests (three repeated measures). Intraclass correlation estimates (ICC ± 95% confidence intervals (CI)) were calculated (mean-rating, absolute-agreement, 2-way mixedeffects model). Paired t-tests assessed differences between right and left areas. No significant differences existed for transverse plane-cuts (scapula, T18 P>0.05) between light-scans. Right and left areas were significantly different at the withers (P=0.012) with the left side larger in 70% of scans, but no significant differences were found between sides at T18. No differences existed for different plane-cuts of the same horse (P=0.53; ICC: 0.76; CIs: 0.43-0.92). While reliability was reduced between all raters (P=0.02; ICC: 0.70; CIs: 0.56-0.82), no significant differences occurred between two different assessors experienced in using the software (P=0.88; ICC: 0.90; CIs: 0.82-0.95). Intra-rater reliability for assessing thoracic profile and inter-rater reliability ICC values with experienced analysts was interpreted as good/excellent. The results suggest 3D light-scanning is an objective, non-invasive method to record size and symmetry of the epaxial region in horses and warrants validity testing against current measurement methods such as the flexible-curve ruler.","PeriodicalId":10709,"journal":{"name":"Comparative Exercise Physiology","volume":"12 1","pages":""},"PeriodicalIF":0.6000,"publicationDate":"2022-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Comparative Exercise Physiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3920/cep220016","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Equine epaxial muscle size, thoracolumbar profile and symmetry in horses is of clinical interest due to relationships with pain and pathology. Flexible-curve rulers have previously been used to gather reliable, objective measures of thoracic profile, however, 3D light-scanning offers a potential non-contact alternative method to estimate cross sectional area (CSA) of the region. 3D light-scans of the thoracic epaxial region were taken from ten endurance horses (7 geldings, 3 mares; 8±2 years). Total CSA of the combined epaxial musculature, using computer software, was calculated at scapula and T18 levels (depth: 15 cm). Intra and inter-rater (n=3) reliability of CSA measurements was assessed using Friedman’s analyses and post-hoc Wilcoxon rank tests (three repeated measures). Intraclass correlation estimates (ICC ± 95% confidence intervals (CI)) were calculated (mean-rating, absolute-agreement, 2-way mixedeffects model). Paired t-tests assessed differences between right and left areas. No significant differences existed for transverse plane-cuts (scapula, T18 P>0.05) between light-scans. Right and left areas were significantly different at the withers (P=0.012) with the left side larger in 70% of scans, but no significant differences were found between sides at T18. No differences existed for different plane-cuts of the same horse (P=0.53; ICC: 0.76; CIs: 0.43-0.92). While reliability was reduced between all raters (P=0.02; ICC: 0.70; CIs: 0.56-0.82), no significant differences occurred between two different assessors experienced in using the software (P=0.88; ICC: 0.90; CIs: 0.82-0.95). Intra-rater reliability for assessing thoracic profile and inter-rater reliability ICC values with experienced analysts was interpreted as good/excellent. The results suggest 3D light-scanning is an objective, non-invasive method to record size and symmetry of the epaxial region in horses and warrants validity testing against current measurement methods such as the flexible-curve ruler.
期刊介绍:
''Comparative Exercise Physiology'' is the only international peer-reviewed scientific journal specifically dealing with the latest research in exercise physiology across all animal species, including humans. The major objective of the journal is to use this comparative approach to better understand the physiological, nutritional, and biochemical parameters that determine levels of performance and athletic achievement. Core subjects include exercise physiology, biomechanics, gait (including the effect of riders in equestrian sport), nutrition and biochemistry, injury and rehabilitation, psychology and behaviour, and breeding and genetics. This comparative and integrative approach to exercise science ultimately highlights the similarities as well as the differences between humans, horses, dogs, and other athletic or non-athletic species during exercise. The result is a unique forum for new information that serves as a resource for all who want to understand the physiological challenges with exercise.