{"title":"Medical ultrasonic transducers with switchable frequency bands centered about f/sub 0/ and 2f/sub 0/","authors":"T. R. Gururaja, A. Shurland, J. Chen","doi":"10.1109/ULTSYM.1997.663314","DOIUrl":null,"url":null,"abstract":"We present a novel type of ultrasonic imaging transducer in which the operating frequency can be switched between two distinct bands centered about f/sub 0/ and 2f/sub 0/. In effect, we can achieve greater than 100% transducer bandwidth at the -6 dB level. The transducer is based on using DC bias induced piezoelectricity in electrostrictive materials such as lead magnesium niobate-lead titanate (PMN-PT) relaxor ferroelectric materials.","PeriodicalId":6369,"journal":{"name":"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)","volume":"1 1","pages":"1659-1662 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"1997-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.1997.663314","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

We present a novel type of ultrasonic imaging transducer in which the operating frequency can be switched between two distinct bands centered about f/sub 0/ and 2f/sub 0/. In effect, we can achieve greater than 100% transducer bandwidth at the -6 dB level. The transducer is based on using DC bias induced piezoelectricity in electrostrictive materials such as lead magnesium niobate-lead titanate (PMN-PT) relaxor ferroelectric materials.
以f/sub 0/和2f/sub 0/为中心的可切换频带的医用超声换能器
我们提出了一种新型超声成像换能器,其工作频率可以在以f/sub 0/和2f/sub 0/为中心的两个不同波段之间切换。实际上,我们可以在-6 dB级别实现大于100%的换能器带宽。该换能器基于在电致伸缩材料(如铌镁铅-钛酸铅(PMN-PT)弛豫或铁电材料)中使用直流偏压诱导压电。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信