D. Stellas, M. T. Hansen, Torbjörn Thiringer, T. Stroømsvik, H. B. Ulvestad
{"title":"Position-sensorless control of a submersible PMSM fed over a long cable and two transformers","authors":"D. Stellas, M. T. Hansen, Torbjörn Thiringer, T. Stroømsvik, H. B. Ulvestad","doi":"10.1109/EPE.2014.6910696","DOIUrl":null,"url":null,"abstract":"This paper proposes the combination of two sensorless control algorithms for the secure start-up and the efficient operation of a remotely-controlled PMSM. V / f control is applied during the start-up of the motor and vector control is used for operation at higher speeds. The investigated system consists of a long step-out configuration with a cable and two transformers between the PMSM and its VSD. The system is tested with simulations and with experiments on a lab model. The results demonstrate that V / f control can safely start the PMSM. The effect of the inertia of the rotating assembly, the load torque and the initial rotor position on the start-up performance of the system is investigated and the successful transition from V / f control to vector control is demonstrated.","PeriodicalId":6508,"journal":{"name":"2014 16th European Conference on Power Electronics and Applications","volume":"46 1","pages":"1-10"},"PeriodicalIF":0.0000,"publicationDate":"2014-09-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 16th European Conference on Power Electronics and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPE.2014.6910696","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
Abstract
This paper proposes the combination of two sensorless control algorithms for the secure start-up and the efficient operation of a remotely-controlled PMSM. V / f control is applied during the start-up of the motor and vector control is used for operation at higher speeds. The investigated system consists of a long step-out configuration with a cable and two transformers between the PMSM and its VSD. The system is tested with simulations and with experiments on a lab model. The results demonstrate that V / f control can safely start the PMSM. The effect of the inertia of the rotating assembly, the load torque and the initial rotor position on the start-up performance of the system is investigated and the successful transition from V / f control to vector control is demonstrated.