{"title":"Determination of antimony in brass by on-line hydride generation fluorescence spectrometry in alkaline solution","authors":"Jin Zexiang, Tang Zhiyong, Qiu Haiou, Hu Shenghong","doi":"10.1002/(SICI)1098-2728(2000)12:2<114::AID-LRA12>3.0.CO;2-W","DOIUrl":null,"url":null,"abstract":"<p>Antimony was determined in alloy copper by on-line hydride generation atomic fluorescence spectrometry in an alkaline solution. Samples were dissolved with nitric acid. In order to eliminate serious chemical interferences caused by transition metals, the solution was then made alkaline with sodium hydroxide. Conditions for hydride generation in alkaline medium and parameters of the flow injection system were optimized. Compared with the traditional procedure for hydride generation, the proposed procedure is simple and effective. The method was used successfully for the determination of antimony in standard brass samples. © 2000 John Wiley & Sons, Inc. Lab Robotics and Automation 12:114–117, 2000</p>","PeriodicalId":100863,"journal":{"name":"Laboratory Robotics and Automation","volume":"12 2","pages":"114-117"},"PeriodicalIF":0.0000,"publicationDate":"2000-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/(SICI)1098-2728(2000)12:2<114::AID-LRA12>3.0.CO;2-W","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laboratory Robotics and Automation","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/%28SICI%291098-2728%282000%2912%3A2%3C114%3A%3AAID-LRA12%3E3.0.CO%3B2-W","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Antimony was determined in alloy copper by on-line hydride generation atomic fluorescence spectrometry in an alkaline solution. Samples were dissolved with nitric acid. In order to eliminate serious chemical interferences caused by transition metals, the solution was then made alkaline with sodium hydroxide. Conditions for hydride generation in alkaline medium and parameters of the flow injection system were optimized. Compared with the traditional procedure for hydride generation, the proposed procedure is simple and effective. The method was used successfully for the determination of antimony in standard brass samples. © 2000 John Wiley & Sons, Inc. Lab Robotics and Automation 12:114–117, 2000
碱性溶液中在线氢化物发生荧光光谱法测定黄铜中的锑
采用在线氢化物发生原子荧光光谱法在碱性溶液中测定合金铜中的锑。样品用硝酸溶解。为了消除过渡金属造成的严重的化学干扰,然后用氢氧化钠使溶液呈碱性。优化了在碱性介质中生成氢化物的条件和流动注射系统的参数。与传统的氢化物生成工艺相比,该工艺简单有效。该方法可用于标准黄铜样品中锑的测定。©2000 John Wiley &儿子,Inc。实验室机器人与自动化,2000:114 - 117
本文章由计算机程序翻译,如有差异,请以英文原文为准。