{"title":"Semiautomatic determination of ferrous iron in iron ore using a flow-injection technique","authors":"Soulin Lin, He Man, Zheng Shu","doi":"10.1002/(SICI)1098-2728(2000)12:2<86::AID-LRA7>3.0.CO;2-K","DOIUrl":null,"url":null,"abstract":"<p>A semiautomatic method for mineral-phase analysis for ferrous iron (FeCO<sub>3</sub>) using on-line leaching technique was developed. A flow-injection manifold is described, which makes on-line leaching of the powdered sample followed by color developing of Fe(II) with o-phenanthroline and its spectrophotometric determination possible. This method can produce meaningful results provided that the experimental conditions are kept at optimum values. The analysis time is greatly reduced by using flow injection techniques. Sample throughput was about 12 samples/hr with a method precision of 2.7% RSD, depending on the leaching time chosen and FeCO<sub>3</sub> content in ores. Analytical data were in good agreement with recommended values for analysis of standard references materials. For each analysis, 20–30 mg of powdered sample was required. © 2000 John Wiley & Sons, Inc. Lab Robotics and Automation 12:86–90, 2000</p>","PeriodicalId":100863,"journal":{"name":"Laboratory Robotics and Automation","volume":"12 2","pages":"86-90"},"PeriodicalIF":0.0000,"publicationDate":"2000-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/(SICI)1098-2728(2000)12:2<86::AID-LRA7>3.0.CO;2-K","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laboratory Robotics and Automation","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/%28SICI%291098-2728%282000%2912%3A2%3C86%3A%3AAID-LRA7%3E3.0.CO%3B2-K","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
A semiautomatic method for mineral-phase analysis for ferrous iron (FeCO3) using on-line leaching technique was developed. A flow-injection manifold is described, which makes on-line leaching of the powdered sample followed by color developing of Fe(II) with o-phenanthroline and its spectrophotometric determination possible. This method can produce meaningful results provided that the experimental conditions are kept at optimum values. The analysis time is greatly reduced by using flow injection techniques. Sample throughput was about 12 samples/hr with a method precision of 2.7% RSD, depending on the leaching time chosen and FeCO3 content in ores. Analytical data were in good agreement with recommended values for analysis of standard references materials. For each analysis, 20–30 mg of powdered sample was required. © 2000 John Wiley & Sons, Inc. Lab Robotics and Automation 12:86–90, 2000
用流动注射技术半自动测定铁矿石中的亚铁
提出了一种在线浸出法半自动化分析亚铁(FeCO3)矿相的方法。描述了一种流动注射管,它使粉末样品在线浸出,然后用邻菲罗啉显色铁(II)及其分光光度测定成为可能。只要实验条件保持在最佳值,该方法可以得到有意义的结果。采用流动注射技术可大大缩短分析时间。样品吞吐量约为12个样品/小时,方法精密度为2.7% RSD,具体取决于所选择的浸出时间和矿石中FeCO3的含量。分析数据与标准参考物质分析的推荐值吻合良好。每次分析需要20-30毫克粉末样品。©2000 John Wiley &儿子,Inc。实验室机器人与自动化(12):86 - 90,2000
本文章由计算机程序翻译,如有差异,请以英文原文为准。