Analisis Pengujian Kinerja Generator Circuit Breaker (GCB) Unit 1 PT.PLN (Persero) UPK Sebalang Sebelum dan Setelah Maintenance

Hamimi Hamimi, Yenni Afrida, Elvin Nursandi
{"title":"Analisis Pengujian Kinerja Generator Circuit Breaker (GCB) Unit 1 PT.PLN (Persero) UPK Sebalang Sebelum dan Setelah Maintenance","authors":"Hamimi Hamimi, Yenni Afrida, Elvin Nursandi","doi":"10.36269/jtr.v5i1.1241","DOIUrl":null,"url":null,"abstract":"Generator Circuit Breaker (GCB) is a circuit breaker that connects electrical energy between the generator of a generator and the electrical network system. Circuit breaker is an electrical device that functions automatically to prevent damage to the electrical circuit due to ashort circuit,overload, andgrounding. faults. This research method was obtained through direct observation and reading the manual book of PT. PLN (Persero) UPK Sebalang unit 1 which is located at Lintas Sumatera Street Km. 22 Sebalang Hamlet, Tarahan Village, Katibung District, South Lampung Regency. The purpose of this study is to find out the results of the analysis of the performance testing of GCB unit 1 PLTU Sebalang both before and after maintenance. The results of the research and analysis of GCB unit 1 PLTU Sebalang changed after maintenance, so that the performance value of the simultaneous contact for the position open was 50%, theposition closed was 46%, the contact resistance for the R phase was 23.5%, the S phase resistance value was 38.7%, and the value of phase T resistance is 33.8%, as well as insulation resistance changes when theposition is open phase R1.4%, phase S is 1.2%, and phase T is 1.1%, for the close phase R 1.8%, phase S 1.1%, phase T 1.2%. This matter shows that the performance value in good condition.","PeriodicalId":31626,"journal":{"name":"Volt Jurnal Ilmiah Pendidikan Teknik Elektro","volume":"8 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volt Jurnal Ilmiah Pendidikan Teknik Elektro","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.36269/jtr.v5i1.1241","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Generator Circuit Breaker (GCB) is a circuit breaker that connects electrical energy between the generator of a generator and the electrical network system. Circuit breaker is an electrical device that functions automatically to prevent damage to the electrical circuit due to ashort circuit,overload, andgrounding. faults. This research method was obtained through direct observation and reading the manual book of PT. PLN (Persero) UPK Sebalang unit 1 which is located at Lintas Sumatera Street Km. 22 Sebalang Hamlet, Tarahan Village, Katibung District, South Lampung Regency. The purpose of this study is to find out the results of the analysis of the performance testing of GCB unit 1 PLTU Sebalang both before and after maintenance. The results of the research and analysis of GCB unit 1 PLTU Sebalang changed after maintenance, so that the performance value of the simultaneous contact for the position open was 50%, theposition closed was 46%, the contact resistance for the R phase was 23.5%, the S phase resistance value was 38.7%, and the value of phase T resistance is 33.8%, as well as insulation resistance changes when theposition is open phase R1.4%, phase S is 1.2%, and phase T is 1.1%, for the close phase R 1.8%, phase S 1.1%, phase T 1.2%. This matter shows that the performance value in good condition.
发电机断路器(GCB)是在发电机的发电机和电网系统之间连接电能的断路器。断路器是一种自动工作的电气装置,可防止因短路、过载和接地而损坏电路。的缺点。本研究方法是通过直接观察和阅读PT. PLN (Persero) UPK Sebalang 1单元的手册获得的,该单元位于南楠榜县Katibung区Tarahan村Lintas sumata Street Km. 22 Sebalang哈姆雷特。本研究的目的是找出PLTU西巴郎1号机组维修前后的性能测试分析结果。GCB单元的研究和分析的结果1 PLTU Sebalang改变了维修之后,这样的性能价值同时接触的位置打开为50%,处境是46%,关闭的接触电阻R相为23.5%,S期阻力值是38.7%,和相T电阻的值是33.8%,以及绝缘电阻变化时处境R1.4%开放阶段,阶段是1.2%,和T期为1.1%,近阶段R 1.8%,S相1.1%,T相1.2%。此事表明,性能值处于良好状态。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
24 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信